Case: T06FR02422
Case Details
Entered Date:
08/15/2006
Applicant:
AU MITCHELL S & ANGEL C JT/RS
Description:
FIRE INSPECTION CHECK LIST USED
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR02422
Case Description: INSPECTION
Total Completed Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2007 | VIOL - FIRE PROTECTION SYSTEMS | MWAINWRI | Approved | 2003 IFC 907.2.10 Smoke alarms Check for operation and location. Min. is bedrooms and hallway. REPAIR SMOKE ALARM IN KITCHEN AND ADD A SMOKE ALARM IN STORAGE ROOM IN NORTH BEDROOM. |
| 01/11/2007 | VIOL - MEANS OF EGRESS | MWAINWRI | Approved | 2003 IFC 1026.5 Emergecy ligting Required in Group R if over 10, and must have 2 exits. Exception: If each sleeping room has a direct exit to the outside. REPAIR EMERGENCY LIGHTING IN MAIN HALLWAY. |
| 01/11/2007 | VIOL - BUILDING SVCS & SYSTEMS | MWAINWRI | Approved | 2003 IFC TFC 603.1 & 316.2 Fuel fired appliances and house cleaning. Furnaces, dryer and hot water heaters are all heat sources and must be maintained and cleaned. CLEAN BEHING DRYER AND CHECK FOR LEAKS IN DUCT. |
| 01/11/2007 | VIOL - BUILDING SVCS & SYSTEMS | MWAINWRI | Approved | 2003 IFC 605.4 Multi-plugs and power-taps UL listed,No end to end, home made. REMOVE MULTIPLUG ADAPTER BEHIND TV IN LIVING ROOM MAY USE A POWER STRIP. |
| 01/11/2007 | VIOL - BUILDING SVCS & SYSTEMS | MWAINWRI | Approved | 2003 IFC 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection. REMOVE EXTENSION CORD IN PANTRY CLOSET. |
| 01/11/2007 | VIOL - PRECAUTION AGAINST FIRE | MWAINWRI | Approved | 2003 IFC 304.1.2 Excessive combustibles Must be safe for non self preserving residents. Weeds over 6” high, Look at alleys and around gas meters. Laddering of vegetation to home. TRIM ALL TREES 3 FEET BACK FROM BUILDING. |
| 01/11/2007 | INSP - FULL | MWAINWRI | Approved |