Case: T06FR01634
Case Details
Entered Date:
05/31/2006
Applicant:
SMITH MARCELINE C
Description:
numerous fire code violations in commercial kitchen.
Outstanding Inspections
Case Number: T06FR01634
Case Status: COMPLETE
Case Description: COMPLAINT (COMMERCIAL)
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/31/2006 | INSP - FULL | RDUARTE | Correction Required | Shooters Steak House & Saloon with numerous fire code violations in commercial kitchen. |
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR01634
Case Description: COMPLAINT (COMMERCIAL)
Total Completed Inspections - 10
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/06/2002 | VIOL - FIRE RESIST.RATED CONST | DRAMIREZ | Approved | TFC 703.1 Opening in the ceiling over the exterior door in kitchen area shall be protected from passage of smoke or fire. |
| 02/06/2002 | VIOL - COMPRESSED GASES | DRAMIREZ | Approved | TFC 3003.5 Secure compressed gas cylinders. 1.) behind bar, south end corner. 2.) outside area, next to coolers. |
| 02/06/2002 | VIOL - MEANS OF EGRESS | DRAMIREZ | Approved | TFC 1011.1 Provide exit sign over exterior door in the billiards room area. |
| 02/06/2002 | VIOL - MEANS OF EGRESS | DRAMIREZ | Approved | TFC 1006.3 Emergency back-up lightung shall be provided. 1.) main bar area. 2.) main dining room area. 3.) billards room area. |
| 06/02/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC 904.11 Current hood system is not in compliance. Shall comply in accordance to following codes: 1.) 609.1 ( Requirments of the International Mechanical Code) 2.) 609.2 ( Type of hood system required) 3.) 904.11 ( Installation and testing) |
| 06/02/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC 906.7 Portable extinguishers shall be on hangers and accesseble. |
| 06/02/2006 | VIOL - PRECAUTION AGAINST FIRE | DRAMIREZ | Approved | TFC 308.3.1 Open flame cooking devices shall not be operated within 10 feet of combustible construction. |
| 06/02/2006 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.5 Extension cords shall not be a subsitute for permanent wiring. 1.) outside office, running through ceiling. 2.) over exit door, kitchen area. 3.) outside cooler area. |
| 06/02/2006 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.3 Shall maintain a clear and working space around electrical panel. |
| 06/02/2006 | COMPL - INITIAL INSPECTION | DRAMIREZ | Approved | 1.) Pre-citation issued. Non-compliant hood system. Was given one week to present documentation indicating that permit was issued showing intent to upgrade or replace hood system. 2.) Deep fryer appliances RED TAGGED. Required seperation between open flame and fryers. 3.) Initiated full inspection. |