OPERATIONS FIRE INSPECTION CHECK LIST USED

Completed Inspections

Case Status: COMPLETE
Case Number: T06FR01108
Case Description: INSPECTION
Total Completed Inspections - 9
End Date Description Inspector Results Comments
05/01/2006 VIOL - MEANS OF EGRESS SHIGGINB Approved 31. TFC 1026.5 Emergecy ligting Required in Group R if over 10, and must have 2 exits. Exception: If each sleeping room has a direct exit to the outside.
05/01/2006 VIOL - FIRE RESIST.RATED CONST SHIGGINB Approved 18.TFC 703.1Must be repair w/ fire resistive materials Look behind washers and dryers, hot water heaters, heater closets
05/01/2006 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved 32. TFC 907.2.10 Smoke alarms Check for operation and location. Min. is bedrooms and hallway
05/01/2006 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved 15. TFC 901.6.2 Records of all system inspections, tests, and maintenance required by the referenced standards shall be maintained on the premises for a minimum of 3 years and made available to the fire code official upon request.
05/01/2006 VIOL - ADMINISTRATION SHIGGINB Approved 12. TFC 102.3 Change of use of a building Must have it posted, must have correct occupancy type, and licensed amount must match occupancy class. R3 or R4M Date of C/O defines TFC used for regulation. 1. C OF O FROM 1993
05/01/2006 VIOL - PRECAUTION AGAINST FIRE SHIGGINB Approved 23.TFC 603.1 & 316.2 Fuel fired appliances and house cleaning. Furnaces, dryer and hot water heaters are all heat sources and must be maintained and cleaned.
05/01/2006 VIOL - PRECAUTION AGAINST FIRE SHIGGINB Approved 11. TFC 310 No smoking inside. If evidence of smoking they must create a designed smoking area out side with astray. We wait to remove heat sources from inside the home.
05/01/2006 VIOL - FIRE SERVICE FEATURES SHIGGINB Approved 1. TFC 2003 505.1 Addressing All building will have approved address numbers plainly legible & visible from the street fronting the property. Min. 3” high w/ contrasting background.
05/01/2006 INSP - FULL SHIGGINB Approved ASL LIC FOR 8