Case: T06FR00828
Case Details
Entered Date:
04/19/2006
Applicant:
MORENO FRANCISCO & MARIA ELENA JT/RS
Description:
Full fire inspection checlist used
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR00828
Case Description: INSPECTION
Total Completed Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2006 | VIOL - COMPRESSED GASES | SHIGGINB | Approved | 36.TFC 3004.1 O2 storage and Use Can be on a 45 degree, Must be secured w/ straps or rack No smoking signs must be posted on front door |
| 04/19/2006 | VIOL - MEANS OF EGRESS | SHIGGINB | Approved | 26.TFC 1008.18 Door operation No double key dead-bolt locks, no special knowledge needed, no slide bolt locks. Only one unlatching device, 27.TFC 1027.3 Egress pathway clear All path ways to all exits required or not. This includes exits from windows Except group R’s can have night latch, indicating dead bolt, or security chain on exits only |
| 04/19/2006 | VIOL - PRECAUTION AGAINST FIRE | SHIGGINB | Approved | 22. TFC 316.1 & 605.7 Electrical and gas appliances Electrical needs UL listing. Check gas connections 23.TFC 603.1 & 316.2 Fuel fired appliances and house cleaning. Furnaces, dryer and hot water heaters are all heat sources and must be maintained and cleaned. |
| 04/19/2006 | VIOL - BUILDING SVCS & SYSTEMS | SHIGGINB | Approved | 6. TFC 605.1 Abatement of electrical hazards Exposed electrical wires , covers, and panels locked. Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage. 1. removed electrical wire from front porch 2.Place elecrtical wire on back porch in conduit |
| 04/19/2006 | INSP - FULL | SHIGGINB | Approved | This is a r4 asl under 1988 ufc, * x 12 shed on side of home is storages only, no violation |