Case: T06DV02527
Case Details
Entered Date:
11/30/2006
Applicant:
CHENG HOLDINGS LIMITED PARTNERSHIP
Description:
PROBLEMS SINCE MOVING IN//HIGH WEEDS//MICE IN HOUSE, HOLES IN WALLS, PELLETS, HEARS THE MICE INSIDE THE WALLS, TV WILL TURN OFF AND ON /REPORTED TO LANDLORD//NOTHING HAS BEEN DONE//KITCHEN SINK IS PLUGGED FOR 2 MONTHS. PLS CALL MARIA B4 INSPECTING *2ND CALL* 12/8/06 CALLER STATES RODENT INFESTATION/TRULY NOLAN HAS BEEN OUT, BUT NOTHING HAS BEEN DONE. STATES PROBLEM IS GETTING WORSE. ADVISED CALLER CSR WAS SCHEDULING THIS FOR AN INITIAL INSPECITON ON 12/11/06.
Outstanding Inspections
Case Number: T06DV02527
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2008 | VIOL - ILLEGAL ACCESSORY STRUC | RMENDOZA | Item closed | |
| 05/07/2008 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | RMENDOZA | Item closed | |
| 05/07/2008 | VIOL(EL) - CIRCUITS | RMENDOZA | Item closed | |
| 05/07/2008 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 05/07/2008 | VIOL(EL) - FIXTURES | RMENDOZA | Item closed | |
| 05/07/2008 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
| 05/07/2008 | NPO(PL)-SEWAGE DISPOSAL (SYS) | RMENDOZA | Item closed | |
| 05/07/2008 | VIOL(PL) - FIXTURES | RMENDOZA | Item closed | |
| 05/07/2008 | NPO(PL)-WATER HEATERS | RMENDOZA | Item closed | |
| 05/07/2008 | VIOL(SA) - KITCHEN | RMENDOZA | Item closed | |
| 05/07/2008 | NPO - INSECTS/PESTS | RMENDOZA | Item closed | |
| 05/07/2008 | NPO - SMOKE ALARMS | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T06DV02527
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2006 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | BEDROOM/BATHROOM ADDITION ON THE NORTHEAST SIDE OF THE STRUCTURE. ROOM ADDITION ON THE SOUTHEAST SIDE OF THE STRUCTURE. PORCH ATTACHED TO THE REAR OF THE STRUCTURE SPANNING APPROX 12 FEET USING 2X4 AS RAFTERS AND APPROX 40 INCHES ON CENTER. LARGE WOOD AWING IN THE REAR YARD APPROX 30X30. DWELLING LACKS SMOKE DETECTORS EXPOSED AND ENERGIZED WIRING IN THE NORTHEAST BEDROOM BEHIND THE DOOR. GFCI IN BEDROOM BATHROOM DOES NOT OPERATE AS INTENDED. LIVING ROOM ELECTRICAL OUTLET NEAR THE HALLWAY SHOWS REVERSE POLARITY. MAIN BATHROOM LACKS LIGHT FIXTURE COVER. GFCI DOES NOT OPERATE AS INTENDED. OUTLET IN THE HALLWAY SHOWS OPEN GROUND. COVER MISSING ON LIGHT SWITCH EXPOSING ENERGIZED WIRES. BEDROOM ON THE SOUTHWEST PORTION OF THE STRUCTURE ELECTRICAL OUTLETS SHOW REVERSE POLARITY. BEDROOM ON THE SOUTHEAST PORTION OF THE STRUCTURE ELECTRICAL OUTLETS SHOW OPEN GROUND. OUTLET INSTALLED OUTSIDE REAR OF STRUCTURE OVER THE DOORWAY. NOT GFI PROTECTED. ROMEX WIRING LEADING FROM CIRCUIT CONNECTS TO A LIGHT FIXTURE WITH EXPOSED ROMEX. WASHER UNDER PORCH AREA IS CONNECTED WITH AN EXTENSION CORD TO OUTLET ABOVE DOORWAY. DRYER IS CONNECTED WITH EXPOSED 12 GAUGE WIRE TO ALTERNATE SERVICE PANEL (FOR REAR UNIT) MAIN SERVICE PANEL 70AMP SERVICE SHOWS DOUBLE LUGGING, WIRING NOT CONNECTED, ENERGIZED AND TOUCH GROUND WIRES,.LACKS PROPER LABELING AND ADDRESSING. WATER IS DRAING FROM THE KITCHEN DISPOSAL INTO THE DISHWASHER. SHOWER CONNECTION IN THE NORTHEAST BATHROOM LEAKS BADLY. WATER DRAIN CONNECTION TO WASHER IS NOT PROPERLY ANCHORED AND NOT PROTECTED. SEPTIC CLEANOUT LACKS PROPER COVER. WATER HEATER LACKS VENT PIPE AND ENCLOSURE. EVIDENCE OF RODENT INFESTATION. HOLES IN THE WALL NEAR HALLWAY. GAPS IN THE KITCHEN CABINET AREA NEAR FLOOR SHOW SIGNS OF RODENT ACTIVITY. ULTRAVIOLAET LIGHT SHOWS SIGNS OF URINE IN WALLS THROUGHOUT THE DWELLING. PRC IS BLANK. UNABLE TO FIND PERMITS FOR REAR ADDITIONS. RM |
| 03/01/2007 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | PERMIT T07CM00681 PULLED ON 2/21/07. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T06DV02527
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 12/26/2007 | CONTACTED BY PHONE |
| 12/14/2006 | CONTACTED BY MAILING |
| 05/07/2008 | VIOLATION CLOSED |
| 03/31/2008 | RESEARCH |