Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/22/2006

Applicant:

QUIHUIS-LOPEZ DIANA M

Description:

BUG INFESTATION, NO THRESHOLDS UNDER FRONT DOOR, MICE, ANTS, NO LOCKS, OPEN SEWER CLEAN OUT ON FRONT PORCH, GAS LINE IN STOVE BIG HOLE, LEAKS IN LIVING ROOM CEILING; NO LOCK OR SCREENS ON BEDROOM WINDOWS. SWAMP COOLER OLD ONE ON SIDE OF ROOF, HUSBAND HAD TO REPLACE, MGR WOULDN'T DO ANYTHING. HAS 3 YOUNG KIDS. **PLEASE CALL TENANT PRIOR TO INSPECTION SO THAT SHE CAN MAKE SURE TO BE HOME** UNIT B HAS ALSO REQUESTED INSPECTION DUE TO MIN HOUSING ISSUES.

Outstanding Inspections

Case Number: T06DV01126
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T06DV01126
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
End Date Description Inspector Results Comments
09/01/2006 INSP - INITIAL CODE ENFORCMENT MCASTRO Approved STOVE PIPE EXPOSED HOLE BEHIND STOVE. CAP ON SEWER NOT PRESENT, NO SCREEN (WINDOWS NO LOCKS), INSECT INFESTATION, CEILING IS LEAKING, NO BASEBOARDS, KITCHEN DOOR-NO THRESHOLD, FRONT DOOR, NO VENTILATION IN BATHROOM, RODENT IN BATHROOM, RODENT HOLE IN CLOSET, SMOKE ALARM NOT WORKING, BATHROOM SINK-PIPES LEAKING, VENT OVER STOVE, MICE DROPPINGS IN CABINET, NO PROPER SEALING ON DOOR KITCHEN, CABINETS NOT CLOSING PROPERLY, ANTS ON KITCHEN, ON LEASE TILL FEBRUARY NOT DELINQUENT IN RENT, NO ADDRESS MARKINGS ON DOOR, COOLER ON TOP OF ROOF. 4 UNIT BUILDING. MARY MACHADO-406-6961 -FRONT WINDOW-NO SEAL, NO LOCKS -FRONT DOOR NO DEADBOLT -KITCHEN WINDOW NO LOCK -STOVE VENT WORKING OUT COVERED W/ BLACK GUNK -KITCHEN DOOR NO DEADBOLT -BATHROOM SINK PLUMBING-DRYWALL BEHIND DEFFICIENT -NO SCREEN ON WINDOWS.
10/19/2006 INSP - FOLLOW UP CODE ENFORCE MCASTRO Approved WORK DONE TO UNITS A & B DID NOT REQUIRE A PERMIT AND THEREFORE DID NOT REQUIRE A LICENSED CONTRACTOR TO PERFORM THE WORK. UNIT A DOES HAVE A SEVERE TERMITE INFESTATION PROBLEM. THE UNIT MUST BE TREATED BY A PEST REMOVAL SPECIALIST.
10/19/2006 INSP - FOLLOW UP CODE ENFORCE MCASTRO Approved THE FOLLOWING ITEMS FOR UNIT A NEED TO BE VERIFIED IF LICENSED CONTRACTOR WAS REQUIRED FOR REPAIRS: 1) MECHANICAL VENTILATION SYSTEM NOT INSTALLED BY LICENSED CONTRACTOR. 2) PLUMBING UNDER SINK WAS NOT REPAIRED BY LICENSED CONTRACTOR. THE FOLLOWING ITEMS FOR UNIT A STILL NEED TO BE CORRECTED: 1) CLEAN-OUT PIPE CAPPED WITH PLASTIC. 2) TERMITES IN THE CEILING (LIVING ROOM AND SMALL BEDROOM) 3) NO LOCKING MECHANISM ON LIVING ROOM WINDOW. UNIT B: 1) PLUMBING REPAIR NOT COMPLETED BY LICENSED CONTRACTOR (NEED TO VERIFY IF LICENSED CONTRACTOR WAS REQUIRED FOR REPAIRS). 2) SMOKE DETECTOR NOT OPERABLE (NO BATTERY).

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T06DV01126
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/11/2006 CONTACTED BY PHONE
09/20/2006 NOTICE OF VIOLATION ISSUED
01/24/2007 VIOLATION CLOSED

Documents

File Name Document Type  
LETTER AND NOTES 9-25 11-13-06 .PDF DOCUMENTS VIEW
LETTER CONTINUED.PDF DOCUMENTS VIEW
NOTES 10-19 10-26-06.PDF DOCUMENTS VIEW
NOTES 1-18-07.PDF DOCUMENTS VIEW
NOV 9-21-06.PDF DOCUMENTS VIEW
2006_09_01_1030A.JPG IMAGES VIEW
2006_09_01_1030B.JPG IMAGES VIEW
2006_09_01_1030C.JPG IMAGES VIEW
2006_09_01_1030D.JPG IMAGES VIEW
2006_09_01_1030E.JPG IMAGES VIEW
2006_09_01_1030F.JPG IMAGES VIEW
2006_09_01_1030G.JPG IMAGES VIEW
2006_09_01_1030H.JPG IMAGES VIEW
2006_09_01_1030I.JPG IMAGES VIEW
2006_09_01_1030J.JPG IMAGES VIEW
2006_09_01_1030K.JPG IMAGES VIEW
2006_09_01_1030L.JPG IMAGES VIEW
2006_09_01_1030M.JPG IMAGES VIEW
2006_09_01_1030N.JPG IMAGES VIEW
2006_09_01_1030O.JPG IMAGES VIEW
2006_09_01_1030P.JPG IMAGES VIEW
2006_09_01_1030Q.JPG IMAGES VIEW
2006_09_01_1030R.JPG IMAGES VIEW
2006_09_01_1030S.JPG IMAGES VIEW
2006_09_01_1030T.JPG IMAGES VIEW
2006_09_01_1030U.JPG IMAGES VIEW
2006_09_01_1030V.JPG IMAGES VIEW
2006_09_01_1100A.JPG IMAGES VIEW
2006_09_01_1100B.JPG IMAGES VIEW
2006_09_01_1100C.JPG IMAGES VIEW
2006_09_01_1100D.JPG IMAGES VIEW
2006_09_01_1100E.JPG IMAGES VIEW
2006_09_01_1100F.JPG IMAGES VIEW
2006_09_01_1100G.JPG IMAGES VIEW
2006_09_01_1100H.JPG IMAGES VIEW
2006_09_01_1100I.JPG IMAGES VIEW
2006_09_01_1100J.JPG IMAGES VIEW
2006_09_01_1100K.JPG IMAGES VIEW
BATHROOMSINK.JPG IMAGES VIEW
BATHROOMSINKB.JPG IMAGES VIEW
BATHROOMVENT.JPG IMAGES VIEW
BEDROOMTERMITES.JPG IMAGES VIEW
CLEANOUT.JPG IMAGES VIEW
HALLSMOKEDETECTOR.JPG IMAGES VIEW
KITCHEN.JPG IMAGES VIEW
KITCHENSINK.JPG IMAGES VIEW
KITCHENSTOVE.JPG IMAGES VIEW
KITCHENTHRESHOLD.JPG IMAGES VIEW
KITCHENVENT.JPG IMAGES VIEW
LROOMBASEBOARDS.JPG IMAGES VIEW
LROOMTERMITES.JPG IMAGES VIEW
LROOMWINDOW.JPG IMAGES VIEW