Case Details

Status:

NOVERIFY

Type:

RES: MINIMUM HOUSING

Entered Date:

07/19/2006

Applicant:

ROUSSEAU FAMILY TR

Description:

COOLER DOESN'T BLOW HARD ENOUGH TO CIRCULATE THROUGH FLOOR, STARTED HAPPENING AFTER ROOF REPLACED. ROOM ADDED WITHOUT PERMITS, ROOF EXPOSED AND JUST METAL. IS BEHIND ON RENT. TENANT IS ATTEMPTING TO MAKE ARRANGEMENTS BUT STATES CANNOT WORK WITH MANAGER/ WILL NOT BE HEARD.

Outstanding Inspections

Case Number: T06DV00922
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
08/02/2006 INSP - INITIAL CODE ENFORCMENT MCOX Violation Returned to property with William Navarro to complete inspection. Porch steps not solid- just concrete block stacked up. Porch wood deteriorating. No violation with cooler- provides adequate cooling to a habitable room. Living room: ceiling light fixture not secured; north window by porch broken out. Kitchen: countertop deteriorated around faucet, needs to be replaced. Hallway ceiling leaking, roof needs to be replaced. West bedroom addition done without permits, incomplete, illegal electrical and arcadia door. Furnace in hallway needs to be serviced, door doesn't shut all the way. Cooler control loose from wall. Ceiling in bedroom falling down, missing closet doors. Smoke alarm doesn't work. Bedroom door deteriorated, doorknob assembly nonfunctioning. Exterior- plumbing vent inadequate, doesn't go thru roof; open electrical circuit at south side of trailer. Shed constructed without permits. Entire electrical system needs to be checked and repaired by licensed contractor- several outlets throughout trailer exhibit hot neutral/reverse polarity. Some of the outlets are ok. MLC

Completed Inspections

Case Status: NOVERIFY
Case Number: T06DV00922
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
01/09/2007 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved VISITED SITE, GATE LOCKED, INSPECTED SITE (VISUAL), UPON INSPECTED FOUND AS FOLLOWS: #9 ON NOV WAS ABATED (PORCH STEPS) #10 WEST BEDROOM WAS DEMOLISHED AND REMOVED, ABATED; #11 EXTERIOR SHED WAS REMOVED, ABATED. WILL CONTACT OWNER DUE TO FW/UP INSPECTION FOR INTERIOR.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00922
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 3
Date Name
07/31/2006 CONTACTED BY PHONE
08/18/2006 CONTACTED BY MAILING
04/23/2009 VIOLATION CLOSED