Case: T06DV00922
Case Details
Entered Date:
07/19/2006
Applicant:
ROUSSEAU FAMILY TR
Description:
COOLER DOESN'T BLOW HARD ENOUGH TO CIRCULATE THROUGH FLOOR, STARTED HAPPENING AFTER ROOF REPLACED. ROOM ADDED WITHOUT PERMITS, ROOF EXPOSED AND JUST METAL. IS BEHIND ON RENT. TENANT IS ATTEMPTING TO MAKE ARRANGEMENTS BUT STATES CANNOT WORK WITH MANAGER/ WILL NOT BE HEARD.
Outstanding Inspections
Case Number: T06DV00922
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected | ||
08/02/2006 | INSP - INITIAL CODE ENFORCMENT | MCOX | Violation | Returned to property with William Navarro to complete inspection. Porch steps not solid- just concrete block stacked up. Porch wood deteriorating. No violation with cooler- provides adequate cooling to a habitable room. Living room: ceiling light fixture not secured; north window by porch broken out. Kitchen: countertop deteriorated around faucet, needs to be replaced. Hallway ceiling leaking, roof needs to be replaced. West bedroom addition done without permits, incomplete, illegal electrical and arcadia door. Furnace in hallway needs to be serviced, door doesn't shut all the way. Cooler control loose from wall. Ceiling in bedroom falling down, missing closet doors. Smoke alarm doesn't work. Bedroom door deteriorated, doorknob assembly nonfunctioning. Exterior- plumbing vent inadequate, doesn't go thru roof; open electrical circuit at south side of trailer. Shed constructed without permits. Entire electrical system needs to be checked and repaired by licensed contractor- several outlets throughout trailer exhibit hot neutral/reverse polarity. Some of the outlets are ok. MLC |
Completed Inspections
Case Status: NOVERIFY
Case Number: T06DV00922
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/09/2007 | INSP - FOLLOW UP CODE ENFORCE | WNAVARRO | Approved | VISITED SITE, GATE LOCKED, INSPECTED SITE (VISUAL), UPON INSPECTED FOUND AS FOLLOWS: #9 ON NOV WAS ABATED (PORCH STEPS) #10 WEST BEDROOM WAS DEMOLISHED AND REMOVED, ABATED; #11 EXTERIOR SHED WAS REMOVED, ABATED. WILL CONTACT OWNER DUE TO FW/UP INSPECTION FOR INTERIOR. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00922
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 3
Date | Name |
07/31/2006 | CONTACTED BY PHONE |
08/18/2006 | CONTACTED BY MAILING |
04/23/2009 | VIOLATION CLOSED |