Case: T06DV00670
Case Details
Entered Date:
06/19/2006
Applicant:
ADAMS RICHARD W
Description:
STEVE HIGGINBOTTOM - TFD - 791.4502 EXT 144 - GROUP HOME INSPECTION - ASSISTED LIVING - NEEDS HELP WITH ELECTRIAL PROBLEMS. PLS CALL STEVE TODAY
Outstanding Inspections
Case Number: T06DV00670
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T06DV00670
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2006 | INSP - INITIAL CODE ENFORCMENT | GGOODMAN | Approved | EXTERIOR 1. FRONT GARAGE MOTION LIGHT IMPROPERLY WIRED 2. GARAGE LIGHTS IMPROPERLY WIRED TO EXSITING LIGHTS 3. OUTLET ON NORTHSIDE OF STORAGE FOR ARCH WELDER MISSING COVER PLATEWORK W/O PERMITS (REMOVE AT WIRING) 4.MOTIN DETECTOR LIGHT N/W COVER OF HOUSE ABOVE EXTERIOR DOOR IS NOT PROPERLY WIRED IN CONDUIT IS BEING "JUMPED" FROM EXSITING PORCH LIGHT 5. CONDUIT FROM JUNCTION BOX ON MAIN HOUSE TO STAGE SHED IN NOT PROPERLY SUPPORTED AND HIGHT TOO LOW 6. #5 COMMUNICATION WIRES NOT PROPERLY SUPPORTED, SHOULD BE IN CONDUIT (FROM HOUSE TO STORAGE. 7. RECR GFGI (BACK WELL) NEEDS TO BE REPLACED OR REMOVED PRONGS BROKEN OFF IN RECETACLE 8. APPEARS WIRING IN SUB-PANAL TO OUTSIDE BAR IS REVERSED, WRONG TYPE BREAKER BOX MAY NOT BE OUTSIDE TYPE BOX 7/19/06 BREAKER REMOVED FROM PANEL TO BAR AREA/ WRES CUT AY REMOVED AT BAR SUB-PANEL AIR HANDLER IN UTILITY ECSEMENT INTERIOR: 1. PANTRY: SUP-PANEL ADDED EXPOSED ROMEX FORM HOLE IN WEST WALL TO SWITCH IN FLEX CONDUIT 7/19/06 2. CONTER GFCI NOT PPROPERLY MAINTAINED MISSING COVER PLATE 3.OUTLET NOT WORKING (TOP HALF) TO REFRIGERATOR 4. SMOKE DETECTOR MISSING S/W REAR HALLWAY 5. APPEARS HOT WATER HEATER LEAKING EVIDENCE BY WATER AT BOTTOM TANK 6. N/E BEDROOM #1 MISSING COVER PLATE STORAGE ROOM: 1. APPEARS STORAGE ROOM HAS BEEN ADDED WITHOUT PERMITS 2. SWITCH & OUTLET MISSING COVER PLATE 3. CEILING OUTLET MISSING COVER PLATE (2) 4. CEILING HIGHT TOO LOW (HEIGHT 6-8" - 6-4") 5. SUB-PANEL DOES NOT HAVE PROPER DOOR OR COVER PLATE (THERE IS ACCES TO BOX) 6. BEAM TO STORAGE NOT PROPERLY SECURED REAR BAR: 1. NO WIRING IN CONDUIT, EXPOSED WIRE NOTS 2. SWITCHES MOUNTED TO THE CEILING 7/19/06 ALL WIRING TO ALL BOXES WAS CUT AND REMOVED |
| 07/19/2006 | INSP - FOLLOW UP CODE ENFORCE | GGOODMAN | Approved | HAROLD ASHTAN 1. PERMIT 13 9532 (26939) HOUSE 86'7" x 36' 7 ROOMS 4 BATHS STORAGE ROOM ATTACHED 2. STORAGE ENCLOSED BATH ADDED JUNE 13 1963 PERMIT BF 1330 INCLUDES ELECTIRCAL CIRCUTS/ MECHANICAL SEPT 25 1997 PLANS APPROVED PERMIT # T97CM01881 1519 SQ FT 2019 UNDER ROOF CERT OF OCCUPANCY 2/11/67 |
| 07/19/2006 | INSP - FOLLOW UP CODE ENFORCE | GGOODMAN | Approved | VISITED SITE CONDUCTED FOLLOW-UP INSPECTION FROM MY NOTES (PRIOR TO INSPECTION FOUND AT RECORDS DEPT ALL PERMITS HAD BEEN PULLED FOR LARGE ADDITION, STORAGE- BATHROOM , AND ALL APPLIANCES AND ELECTRICAL UPGRADES.) INSPECTED EACH ITEM ISSUE BY ISSUE AND FOUND ALL ITEMS TO BE ABATED BUT ONE. REFRIGERATER OUTLET WAS REPLACED BY GFCI BOTH STOVE AND I ASKED HE PUT A STANDERED RECEPTACLE BACK IN ITS PLACE. STEVE HIGINBOTTOM MENTIONED HE WOULD BE BACK IN (2) WEEKS TO INSPECT AGAINTO BE SURE RECEPTEOLE WAS REPLACED I FELT OK WITH THE SITUATION , ALL MY ISSUES WERE ABATED, PICTURES WERE TAKEN. COMPLIANCE CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00670
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/21/2006 | CONTACTED BY PHONE |
| 07/21/2006 | VIOLATION CLOSED |