Case: T06DV00324
Case Details
Entered Date:
04/03/2006
Applicant:
RICHARDS LOIS LEE
Description:
VACANT & NEGLECTED
Outstanding Inspections
Case Number: T06DV00324
Case Status: COMPLIAN
Case Description: VACANT AND NEGLECTED PROGRAM
Total Outstanding Inspections - 14
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected | ||
| NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
| VIOL(BL) - DETACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - ATTACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - FOUNDATION | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
| NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
| NPO(PL)-SEWAGE DISPOSAL (SYS) | None | Not Inspected | ||
| NPO(DL)-VACANT & UNSEC.STRUCT | None | Not Inspected | ||
| VIOL(DL)-NUISANCE STRUCTURE(H) | None | Not Inspected | ||
| VIOL(FS) - HAZARDOUS STORAGE | None | Not Inspected | ||
| 04/04/2006 | INSP - INITIAL CODE ENFORCMENT | JHURD | Correction Required | VISITED SITE, TOOK PICTURES, ON SITE, INSP. COBB (T.F.D.), INSP. VALDEZ (E.S.), INSP. COX (D.S.D.) FOUND ON SITE, CARPORT ALUMINUM ROOF HAZARDOUSLY INSTALLED, ALSO GOES RIGHT UP TO PROPERTY LINE, FRONT PORCH, 2X4 RAFTERS SPANNING APPOX 10', ADDED ELECTRICAL CIRCUIT, ROOF WOOD EAVES DETERIORATING DUE TO LACK OF PROTECTIVE TREATMENT, ADDITIONS ADDED TO SOUTH SIDE OF STRUCTURE, 1 WINDOW BROKEN OUT, STRUCTURE OPEN AND UNSECURED AT THIS TIME, ADDED WATER LINES, WOOD SHED IN REAR YARD SITS ON BOTH PROPERTY LLINES, EAST AND SOUTH, HAS ELECTRIC, ALSO BROKEN WINDOW, OPEN AND UNSECURED, TRASH AND DEBRIS SCATTERED ABOUT YARDS, ANOTHER SHED WEST SIDE ALSO SITS RIGHT ON PROPERTY LINES SOUTH AND WEST. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T06DV00324
Case Description: VACANT AND NEGLECTED PROGRAM
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2007 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | NO VIOLATIONS FOUND AT THIS TIME. CASE CLOSED. MR. |
Completed Activity Special Conditions
Case Description - VACANT AND NEGLECTED PROGRAM
Case Number - T06DV00324
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 06/21/2006 | CONTACTED BY PHONE |
| 05/04/2006 | NOTICE OF VIOLATION ISSUED |
| 12/10/2007 | VIOLATION CLOSED |
| 04/03/2006 | OLD CASE REFERENCE |