Case: T06DV00054
Case Details
Entered Date:
01/13/2006
Applicant:
DORAN WALTER & YOLANDA C JT/RS
Description:
VACANT AND NEGLECTED
Outstanding Inspections
Case Number: T06DV00054
Case Status: COMPLIAN
Case Description: VACANT AND NEGLECTED PROGRAM
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected | ||
| 04/03/2006 | VANS FOLLOW UP INSP | JHURD | Correction Required | VISITED SITE, TOOK PICTURES, STRUCTURE SECURED AT THIS TIME, LACKS NO TRESPASSING SIGNS, YARDS CLEAN, NEW PLYWOOD ON REAR DOOR, NO UTILITIES, ELECTRIC STILL SHOWS ADDED CIRCUITS, DOUBLE LUGGING, (TAGGED FOR D.S.D REVIEW) |
Completed Inspections
Case Status: COMPLIAN
Case Number: T06DV00054
Case Description: VACANT AND NEGLECTED PROGRAM
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2006 | VANS INITIAL INSP | JHURD | Approved | 1/17/06, VISITED SITE, TOOK PICTURES, FRONT ENTRY DOOR SECURED AT THIS TIME, SIDE ENTRY DOOR AT CARPORT SECURED AT THIS TIME, FRONT PATIO ROOF DETERIORATED DUE TO LACK OF PROPER ROOF COVERING ALLOWS FOR WATER TO LEAK ON TO RAFTERS. LIVING ROOM PLATE GLASS WINDOW HAS HOLE THROUGH IT, DOES NOT ALLOW FOR ENTRY, FRONT YARD CLEAN, WEST SIDE, CARPORT SOME DETERIORATION ON CARPORT CEILING, EAST SIDE, ADDED GAS LINE GOING THROUGH WALL INTO ATTIC, WINDOW AC INSTALLED WITH ADDED ELECTIRCAL CIRCUIT. SOUTH, REAR YARD SOME DEBRIS, BEDROOM WINDOW OPEN AND UNSECURED ALLOWS ENTRY INTO STRUCTURE, REAR DOOR TO STRUCTURE OPEN UNSECURED, FRENCH DOORS OPEN UNSECURED, DID ENTER UNIT AS WALKING INTERIOR WAS ABLE TO CLOSE AND SECURE STRUCTURE AT THIS TIME. STORAGE ROOM ADDED ATTCHED TO STRUCTURE, INTERIOR OF SHED SHOWS ADDED ELECTRIC WIRING WITH OPEN AND EXPOSED CONNECTIONS, AND OPEN AND EXPOSED WIRING, ADDED PATIO ROOF, NOT INSTALLED PROPERLY, 2X10'S PLACED TOGETHER, NOTCHED OUT TO FIT RAFTERS INTERGERITY HAS BEEN COMPERMISED, ALSO ROOF TO MAIN STRUCTURE DETERIORATING DUE TO WATER EXPOSURE, 60 AMP. CARTRIDGE FUSE ELECTRICAL SERVICE PANEL SHOWS DETERIORATION, ADDED ELECTRICAL CIRCUITS, DOUBLE LUGGING IN MAIN PANEL ON LOAD AND DISCONNECT SIDES, NETURAL TERMINAL DOUBLE LUGGED, ADDED SUB-PANEL SHOWS DOUBLE LUGGING FOR ADDITIONAL ELECTRICAL CIRCUITS, AT THIS TIME ELECTRICAL SERVICE IS NOT ENERGIZED, GAS SERVICE DISCONTINUED, INTERIOR SHOWS WHERE LIVING ROOM CEILING, HAS DETERIORATED AND FALLEN TO FLOOR DUE TO LACK OF PROPER ROOF COVERINGS, OTHER AREAS EFFECTED ALSO FOR SAME REASON. REAR YARD EAST SIDE BLOCK WALL LIFTING AND BRICKS SEPERATING DUE TO TREE ROOTS. VACANT AND SECURED AT THIS TIME. |
| 11/29/2007 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | VISITED SITE WALKED PERIMETER OF STRUTURE FOUND REAR BOARDED DOOR OPENING HAD THE PLYWOOD REMOVED AND A REAR DOOR INSTALLED AS WELL AS A SCREEN DOOR ABATING THE FINAL ISSUE. DNR HAS NO FURTHER ISSUES AT THIS TIME. |
Completed Activity Special Conditions
Case Description - VACANT AND NEGLECTED PROGRAM
Case Number - T06DV00054
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 02/09/2006 | CONTACTED BY MAILING |
| 02/06/2006 | NOTICE OF VIOLATION ISSUED |
| 12/10/2007 | VIOLATION CLOSED |
| 04/12/2007 | COURT HEARING INFO |
| 06/04/2007 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
| 01/13/2006 | OLD CASE REFERENCE |
| 04/21/2007 | INFORMATION ONLY |