Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

12/19/2005

Applicant:

NZEUKOU GISELE & MARCEL JT/RS

Description:

Pre-License Fire inspection for group home. R3

Completed Inspections

Case Status: COMPLETE
Case Number: T05FR01926
Case Description: INSPECTION
Total Completed Inspections - 8
End Date Description Inspector Results Comments
12/19/2005 INSP - FULL SHIGGINB Approved This a Pre-license fire inspection for an R3 group home Checklist used
12/20/2005 INSP - LIFE SAFETY SHIGGINB Approved 5. TFB AG105.2 Pools and spas protected. Fence required. Location wrong. 27.TFC 1027.3 Egress pathway clear. The fence was required but was place in the pathway of a exit from a bedroom window. Must move fence back behind bebroom window.
12/20/2005 VIOL - PRECAUTION AGAINST FIRE SHIGGINB Approved 2. TFC 2003: 304.1.2 Excessive combustibles Clean Vegetation around gas metter, at lease 3' away.
12/27/2005 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved 33.TFC 2003: 906.1 # 6 Extinguishers required by code official. 1. A 2A-10BC must be mounted near the kitchen area.
12/27/2005 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved 32. TFC 2003: 907.2.10 Smoke alarms Check for operation and location. Min. is bedrooms and hallway. 1. Move somke alarms in bedrooms to the ceiling or to base of beams to maximize coverage.
12/27/2005 VIOL - MEANS OF EGRESS SHIGGINB Approved 26.TFC 2003: 1008.18 Door operation No double key dead-bolt locks, no special knowledge needed, no slide bolt locks. 1. Replace double-key dead bolt, on the front door, with thumb latch dead bolt .
12/27/2005 VIOL - FIRE RESIST.RATED CONST SHIGGINB Approved 18.TFC 2003 703.1Must be repair w/ fire resistive materials 1. Repair ceiling in heater room
12/27/2005 VIOL - BUILDING SVCS & SYSTEMS SHIGGINB Approved 20. TFC 2003: 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection. 1. Extension cords in launtry room and master bedroom need to be removed or replaced with over current protection power taps.