Case Details

Status:

COMPLETE

Type:

COMPLAINT (COMMERCIAL)
Address:

Entered Date:

11/04/2005

Applicant:

ASHLAND GROUP LLC 16.6564% & SWC

Description:

Full Inspection

Completed Inspections

Case Status: COMPLETE
Case Number: T05FR01720
Case Description: COMPLAINT (COMMERCIAL)
Total Completed Inspections - 9
End Date Description Inspector Results Comments
11/08/2005 INSP - FULL DRAMIREZ Approved TFC 1013.4.1 Must maintaine aisle with clearence in stockroom to rear of building.( West wall)
11/09/2005 VIOL - PRECAUTION AGAINST FIRE DRAMIREZ Approved TFC315.2 Storage in N. stockroom shall be orderly.
11/09/2005 VIOL - HIGH PILED COMBUSTIBLES DRAMIREZ Approved TFC2305.4 Aisles in main stockroom must maintained with 44 in. width.
11/09/2005 VIOL - HIGH PILED COMBUSTIBLES DRAMIREZ Approved
11/09/2005 VIOL - BUILDING SVCS & SYSTEMS DRAMIREZ Approved TFC605.1 Cover for water heater must be replaced. TFC605.3 Must maintain 36 in. working space in front of electrical braker panal located on north wall of main stockroom. TFC605.6 Light swich on N. wall next to exet in main stockroom must have an approved cover.
11/09/2005 VIOL - FIRE RESIST.RATED CONST DRAMIREZ Approved
11/09/2005 VIOL - FIRE RESIST.RATED CONST DRAMIREZ Approved TFC703.1 Missing cieling tiles through out building must be replaced.
11/09/2005 VIOL - FIRE PROTECTION SYSTEMS DRAMIREZ Approved TFC901.1 Extinguisher in rear stockroom (west side) must be serviced. TFC901.6 Must maintain 36 in. of clearence around sprkler. riser. TFC901.6 Extinguisher in main stockroom must be serviced. TFC901.6.2 Shall present records of sprkler. syst. annual inspection test.
11/09/2005 VIOL - MEANS OF EGRESS DRAMIREZ Approved 1027.2 required exit located on SE corner must be free from obstruction and remained unlocked during business hrs. 2. Exit to NW shall not be obstructed. 1027.6 Exit door on SEcorner of bld have only one locking device on it (ie thumb turn lock 1013.4.1 must maintaine aisle with 28" clearence in stock room to rear of bld (WS) 1011.1 Exit sign for the NW exit shall be visable from sales floor.