Case Details

Status:

COMPLETE

Type:

COMPLAINT (RESIDENTIAL)

Entered Date:

10/11/2005

Applicant:

MARTINEZ ELVIA & ULLOA ALFONSO PARRA JT/RS

Description:

Complaint Investigation

Outstanding Inspections

Case Number: T05FR01587
Case Status: COMPLETE
Case Description: COMPLAINT (RESIDENTIAL)
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
10/03/2005 INSP - REINSPECTION JLANGEJA Violation TFC 105.6.42- An operational permit is required to conduct a spraying or dipping operation utilizing flammable or combustible liquids or the application of combustible powders regulated by Chapter 15 of the IFC (2003).
10/03/2005 VIOL - FLAMMABLE FINISHES JLANGEJA Violation TFC 1504.1- Spray-finishing operatyions conducted in buildings used for Group R (residential) occupancies shall be located in a spray room protected with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 and separated vertically and horizontally from other areas in accordance with the IBC. *If spray finishing continues, a citation may be issued that will require an appearance in court by you and lead to a probable fine.

Completed Inspections

Case Status: COMPLETE
Case Number: T05FR01587
Case Description: COMPLAINT (RESIDENTIAL)
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/02/2005 COMPL - INITIAL INSPECTION JLANGEJ Approved EN14-C notified on-call inspector (MA28) of resident spraying flammable finishes. Environment non hazardous, Ma28 to follow up in am.