REFERRED

Type:

INSPECTION

Entered Date:

09/13/2005

Applicant:

CARILLION REALTY CORP

Description:

Full Fire Inspection

Outstanding Inspections

Case Number: T05FR01399
Case Status: REFERRED
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
09/13/2005 VIOL - ADMINISTRATION SHIGGINB Violation TFC 2003 102.3 Change of use or occupancy. Refered to DSD for update of the C of O. C of O is for assisted living and different owner

Completed Inspections

Case Status: REFERRED
Case Number: T05FR01399
Case Description: INSPECTION
Total Completed Inspections - 7
End Date Description Inspector Results Comments
09/13/2005 VIOL - BUILDING SVCS & SYSTEMS SHIGGINB Approved TFC 2003 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. 1. Place all electrical wire out side in conduit, back and front porch
09/13/2005 VIOL - FIRE RESIST.RATED CONST SHIGGINB Approved TFC 2003 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. 1. Repair ceiling around vent in heater room
09/13/2005 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved TFC 2003 907.3.1.8 Group R-4. A fire alarm system shall be installed in existing Group R-4 residential care/assisted living facilities. Exceptions: 1. Where there are interconnected smoke alarms meeting the requirements of Section 907.2.10 and there is at least one manual fire alarm box per floor arranged to sound continuously the smoke alarms. 2. Other manually activated, continuously sounding alarms approved by the fire code official.
09/13/2005 VIOL - PRECAUTION AGAINST FIRE SHIGGINB Approved TFC 2003 603.9 Protect gas meters 1. Have southwest gas inspecte gas meters
09/13/2005 INSP - LIFE SAFETY SHIGGINB Approved TFC 2003 Pool and spa code. 1.Reduce the spacing between the fence and wall to less than 4" on the east side. 2. Replace the wire that holds the fence post together.
09/13/2005 VIOL - FIRE SERVICE FEATURES SHIGGINB Approved TFC 2003 505.1 Address numbers. New and existing buildings shall have approved address numbers. 1. Place address at street and on building, 3" high with contrsting background
09/14/2005 VIOL - MEANS OF EGRESS SHIGGINB Approved TFC 2003 1026.5 Illumination emergency power. Emergency exit lighting is requiered in all exsiting group home lic. between 6 and 10. R-4