Case Details

Status:

FIELD

Type:

INSPECTION
Address:

Entered Date:

08/02/2005

Applicant:

WILLIAMS MICHAEL M & LAUER-WILLIAMS JEANNE TR

Description:

inspection

Outstanding Inspections

Case Number: T05FR01198
Case Status: FIELD
Case Description: INSPECTION
Total Outstanding Inspections - 13
End Date Description Inspector Results Comments
INSP - FULL None Not Inspected
07/28/2005 VIOL - ADMINISTRATION JVALENZU Violation 102.6 - Certificate of Occupancy required
07/28/2005 VIOL - FIRE SERVICE FEATURES JVALENZU Violation address numbers shall be in accordance with Pima county requirements
07/28/2005 VIOL - BUILDING SVCS & SYSTEMS JVALENZU Violation 605.3 - a working space of 30''w x 36''d x 78''h shall be provided for electrical service equipment.
07/28/2005 VIOL - BUILDING SVCS & SYSTEMS JVALENZU Violation 605.4 - multiplug adapters shall be prohibited - at stereo/TV
07/28/2005 VIOL - BUILDING SVCS & SYSTEMS JVALENZU Violation 605.5 - extension cords shall not be used as a substitute for permanent wiring - throughout shop
07/28/2005 VIOL - BUILDING SVCS & SYSTEMS JVALENZU Violation 605.5.3 - extension cords shall be maintained in good condition - cords to sanding tables, drill press, band saw, phone, stereo/TV
07/28/2005 VIOL - BUILDING SVCS & SYSTEMS JVALENZU Violation 605.6 - open junction boxes shall be prohibited - cover open spaces in electrical panel
07/28/2005 VIOL - FIRE PROTECTION SYSTEMS JVALENZU Violation 901.6 - portable fire extinguishers shall be tested and inspected annually - shop area
07/28/2005 VIOL - FIRE PROTECTION SYSTEMS JVALENZU Violation 906.3 - portable fire extinguisher shall be rated not less than 4A
07/28/2005 VIOL - FIRE PROTECTION SYSTEMS JVALENZU Violation 906.7 - portable fire extinguisher shall be mounted on hangar or bracket and securely attached to wall - shop area
07/28/2005 VIOL - MEANS OF EGRESS JVALENZU Violation 1026.6 - guards shall be provided on open spaces more than 30'' above the grade below - loading dock area
07/28/2005 VIOL - LUMBER YARD & WOOD FAC. JVALENZU Violation 1903.2 - equipment located inside buildings which generate combustible dust shall be provided with approved dust collection - table saw