Case: T05FR01198
Case Details
Entered Date:
08/02/2005
Applicant:
WILLIAMS MICHAEL M & LAUER-WILLIAMS JEANNE TR
Description:
inspection
Outstanding Inspections
Case Number: T05FR01198
Case Status: FIELD
Case Description: INSPECTION
Total Outstanding Inspections - 13
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FULL | None | Not Inspected | ||
07/28/2005 | VIOL - ADMINISTRATION | JVALENZU | Violation | 102.6 - Certificate of Occupancy required |
07/28/2005 | VIOL - FIRE SERVICE FEATURES | JVALENZU | Violation | address numbers shall be in accordance with Pima county requirements |
07/28/2005 | VIOL - BUILDING SVCS & SYSTEMS | JVALENZU | Violation | 605.3 - a working space of 30''w x 36''d x 78''h shall be provided for electrical service equipment. |
07/28/2005 | VIOL - BUILDING SVCS & SYSTEMS | JVALENZU | Violation | 605.4 - multiplug adapters shall be prohibited - at stereo/TV |
07/28/2005 | VIOL - BUILDING SVCS & SYSTEMS | JVALENZU | Violation | 605.5 - extension cords shall not be used as a substitute for permanent wiring - throughout shop |
07/28/2005 | VIOL - BUILDING SVCS & SYSTEMS | JVALENZU | Violation | 605.5.3 - extension cords shall be maintained in good condition - cords to sanding tables, drill press, band saw, phone, stereo/TV |
07/28/2005 | VIOL - BUILDING SVCS & SYSTEMS | JVALENZU | Violation | 605.6 - open junction boxes shall be prohibited - cover open spaces in electrical panel |
07/28/2005 | VIOL - FIRE PROTECTION SYSTEMS | JVALENZU | Violation | 901.6 - portable fire extinguishers shall be tested and inspected annually - shop area |
07/28/2005 | VIOL - FIRE PROTECTION SYSTEMS | JVALENZU | Violation | 906.3 - portable fire extinguisher shall be rated not less than 4A |
07/28/2005 | VIOL - FIRE PROTECTION SYSTEMS | JVALENZU | Violation | 906.7 - portable fire extinguisher shall be mounted on hangar or bracket and securely attached to wall - shop area |
07/28/2005 | VIOL - MEANS OF EGRESS | JVALENZU | Violation | 1026.6 - guards shall be provided on open spaces more than 30'' above the grade below - loading dock area |
07/28/2005 | VIOL - LUMBER YARD & WOOD FAC. | JVALENZU | Violation | 1903.2 - equipment located inside buildings which generate combustible dust shall be provided with approved dust collection - table saw |