Case: T05FR01043
Case Details
Entered Date:
07/07/2005
Applicant:
3100 LLC
Description:
Full Inspection
Outstanding Inspections
Case Number: T05FR01043
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 10
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2005 | VIOL - BUILDING SVCS & SYSTEMS | TKNAPP | Correction Required | 605.1 The electrical panel at the east room of the west building shall have blanks installed where breakers are missing. |
| 07/07/2005 | VIOL - BUILDING SVCS & SYSTEMS | TKNAPP | Correction Required | 605.5 The extinsion cords in the east building shall not be used as permanent wiring. |
| 07/07/2005 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1008.1.8 The exit door of the northwest room shall not have a lock that requires a key. |
| 07/07/2005 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1008.1.8.3 A readily visible sign stating This door to remain unlocked when building is occupied" shall be installed on the west exit of the west building. |
| 07/07/2005 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1027.2 Exit door in northwest room shall be continuously maintained free from obstructions. |
| 07/07/2005 | VIOL - FLAMMABLE FINISHES | TKNAPP | Correction Required | 1503.2.6 No smoking signs shall be posted in all rooms. |
| 07/07/2005 | VIOL - HAZARDOUS MATERIALS,GEN | TKNAPP | Correction Required | 2703.4 MSDS sheets shall be readily available for all hazardous materials on the premises. |
| 07/07/2005 | VIOL - HAZARDOUS MATERIALS,GEN | TKNAPP | Correction Required | 2703.5 Visible hazard identification signs shall be posted at all entrances to the building where painting is done. |
| 07/07/2005 | VIOL - HAZARDOUS MATERIALS,GEN | TKNAPP | Correction Required | 2703.5.1 Fifty five gallon drums that are empty shall be labled empty. |
| 07/07/2005 | VIOL - FLAMMABLE LIQUIDS | TKNAPP | Correction Required | 3404.3.4.4 Flammable liquids shall be stored in a flammable liquid storage cabinet. |
Completed Inspections
Case Status: COMPLETE
Case Number: T05FR01043
Case Description: INSPECTION
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2005 | INSP - FULL | TKNAPP | Approved |