Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

05/11/2005

Applicant:

KNIAZ WALTER A & FRANCES M X C

Description:

full inspection

Outstanding Inspections

Case Number: T05FR00658
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
VIOL - BUILDING SVCS & SYSTEMS None Not Inspected
VIOL - FIRE PROTECTION SYSTEMS None Not Inspected
VIOL - MEANS OF EGRESS None Not Inspected
VIOL - HAZARDOUS MATERIALS,GEN None Not Inspected
VIOL - COMPRESSED GASES None Not Inspected
05/11/2005 INSP - FULL FCONTRER Correction Required TFC 2605.1.1 welding area: J-box cover plate. TFC 3003.3.3 compress gas cylinder needs to be secured prevent accidents.TFC 605.5 extension cords throughout the business.need to remove.TFC 906.5 Fire extinguishers need to be serviced. TFC 605 multi plugs shall be removed and replaced with power surge protectors.TFC 2703 Label all chemical drums to its product.etc. waste oil tank. TFC 605.5 replace cover plates for J-boxies throughout business.TFC1008.1.8 The back exit door is blocked. shall make exit door clear to exit.

Completed Inspections

Case Status: COMPLETE
Case Number: T05FR00658
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
06/21/2005 VIOL - WELDING & OTHER HOT WRK FCONTRER Approved