Case Number: T05FR00592
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
INSP - FULL None Not Inspected
05/03/2005 VIOL - ADMINISTRATION JLANGEJA Violation TBC 110.1- No building or structure shall be used or occupied...until the building official has issued a Certificate of Occupancy. It can be obtained at Development Services- 201 N Stone.
05/03/2005 VIOL - FIRE SERVICE FEATURES JLANGEJA Violation TFC 504.2- Exterior doors that are rendered non-functional shall have a sign affixed to the exterior side of the door stating "THIS DOOR BLOCKED" in 6" letters on contrasting background.
05/03/2005 VIOL - BUILDING SVCS & SYSTEMS JLANGEJA Violation TFC 605.6- Open wiring splices and open junction boxes shall be prohibited.
05/03/2005 VIOL - FIRE PROTECTION SYSTEMS JLANGEJA Violation TFC 901.6- Fire extinguishers shall be serviced annually. (3)
05/03/2005 VIOL - HAZARDOUS MATERIALS,GEN JLANGEJA Violation TFC 2703.5.1- Individual containers, cartons or packages shall be conspicuously marked or labeled in an approved manner.
05/03/2005 VIOL - COMPRESSED GASES JLANGEJA Violation TFC 3003.3- Compressed gas cylinders shall be secured against accidental dislodgement.
05/03/2005 VIOL - LIQUID PETROLEUM GASES JLANGEJA Violation TFC 3804.1- LPG tanks shall be protected from the weather and vent plug shall be pointed away from structure.