Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

04/27/2005

Applicant:

KIVEL DANIEL & ALVIN TR TRUST A 1/3 &

Description:

Full Inspection

Outstanding Inspections

Case Number: T05FR00539
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
04/27/2005 VIOL - PRECAUTION AGAINST FIRE TKNAPP Correction Required 305.1 The water hose near the stove in the deli shall be removed or relocated so that it no longer produces a fire hazard.
04/27/2005 VIOL - PRECAUTION AGAINST FIRE TKNAPP Correction Required 315.2.1 Storage in stockroom shall be 2 feet below ceiling.
04/27/2005 VIOL - FIRE SERVICE FEATURES TKNAPP Correction Required 505.1 Address numbers shall be posted in accordance with pima county standards.
04/27/2005 VIOL - BUILDING SVCS & SYSTEMS TKNAPP Correction Required 605.5 The extension cord for the bread slicer shall be removed or replaced with a type with overcurrent protection.
04/27/2005 VIOL - BUILDING SVCS & SYSTEMS TKNAPP Correction Required 605.6 Junction boxes in the compressor room shall have approved covers.
04/27/2005 VIOL - FIRE PROTECTION SYSTEMS TKNAPP Correction Required 904.11 The metal filters for the hood system in the deli shall be arranged so that the baffles run vertically and so there are no gaps between the filters.
04/27/2005 VIOL - MEANS OF EGRESS TKNAPP Correction Required 1011.1 Exit access doors shall be marked by an approved sign readily visible from any direction of egress travel. Illuminated exit signs shall be installed in the following areas; at produce prep area at center stockroom exit at doorway near trash compactor at hallway exit near offices at northwest exit from sales floor at west exit from sales floor
04/27/2005 VIOL - MEANS OF EGRESS TKNAPP Correction Required 1013.4.1 A clear aisle shall be maintained in the walk-in freezer.

Completed Inspections

Case Status: COMPLETE
Case Number: T05FR00539
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/10/2005 INSP - FULL TKNAPP Approved