Case: T05FR00241
Case Details
Entered Date:
02/14/2005
Applicant:
TUCSON TEACHERS FEDERAL CREDIT UNION
Description:
Inspection
Outstanding Inspections
Case Number: T05FR00241
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FULL | None | Not Inspected | ||
| 02/14/2005 | VIOL - ADMINISTRATION | JLANGEJA | Violation | TFC 102.4- A Certificate of Occupancy is required to occupy a structure. Call Development Services @ 791-5550 or 201 N Stone to obtain C of O. |
| 02/14/2005 | VIOL - PRECAUTION AGAINST FIRE | JLANGEJA | Violation | TFC 315.2.1- Storage shall be maintained 2 feet or more below the ceiling in a non-sprinklered building. Please remove combustible storage below 2 feet from ceiling. |
| 02/14/2005 | VIOL - FIRE SERVICE FEATURES | JLANGEJA | Violation | TFC 505.1- Address numbers shall be in accordance with Pima County address display requirements. See handout. |
| 02/14/2005 | VIOL - FIRE RESIST.RATED CONST | JLANGEJA | Violation | TFC 703.1- Fire-resistance rated construction shall be maintained. Such elements shall be properly replaced, repaired or restored when damaged, altered, breeched or penetrated. Ceiling tiles near front entrance and in data room missing. |