Case: T05FR00101
Case Details
Entered Date:
01/25/2005
Applicant:
RIDDICK RONALD S & NATALIE G CP/RS
Description:
Inspection
Outstanding Inspections
Case Number: T05FR00101
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 9
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FULL | None | Not Inspected | ||
| 01/18/2005 | VIOL - PRECAUTION AGAINST FIRE | JLANGEJA | Violation | TFC 315.2.1- Storage shall be maintained 2 feet or more below the ceiling in a non-sprinklered building. |
| 01/18/2005 | VIOL - FIRE SERVICE FEATURES | JLANGEJA | Violation | TFC 505.1- Address numbers shall be in accordance with Pima County address requirements. *See handout.* |
| 01/18/2005 | VIOL - BUILDING SVCS & SYSTEMS | JLANGEJA | Violation | TFC 605.3- A working space of not less than 30" in width, 36" in depth and 78" in height shall be provided in front of electrical service panels. (outside) |
| 01/18/2005 | VIOL - BUILDING SVCS & SYSTEMS | JLANGEJA | Violation | TFC 605.4- Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. |
| 01/18/2005 | VIOL - BUILDING SVCS & SYSTEMS | JLANGEJA | Violation | TFC 605.5- Extension cords shall not be a substitute for permanent wiring |
| 01/18/2005 | VIOL - FIRE PROTECTION SYSTEMS | JLANGEJA | Violation | TFC 901.6- Fire extinguishers need to be recharged. |
| 01/18/2005 | VIOL - FIRE PROTECTION SYSTEMS | JLANGEJA | Violation | TFC 906.7- Fire extinguishers shall be installed on hangers or brackets. |
| 01/18/2005 | VIOL - HAZARDOUS MATERIALS,GEN | JLANGEJA | Violation | TFC 2703.1.1- The maximum allowable quantity of inside storage of a flammable gas shall be 3 gallons. The (5) 6 gallon tanks shall be removed from inside the building. |