Inspection

Outstanding Inspections

Case Number: T05FR00074
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
INSP - FULL None Not Inspected
01/18/2005 VIOL - ADMINISTRATION JLANGEJA Violation TFC 102.3- A certificate of occupancy is required for change of ownership, change of use or any modifications done to the building. Contact Development Services at 791-5550. See handouts.
01/18/2005 VIOL - ADMINISTRATION JLANGEJA Violation TFC 102.4- Application of the building code. New structures shall comply with the International Building Code. Repairs, alterations and additions to existing structures shall comply with the IBC or the New Jersey Rehab Subcode.
01/18/2005 VIOL - FIRE SERVICE FEATURES JLANGEJA Violation TFC 505.1- Address numbers shall be in accordance with Pima County address display requirements. See handout.
01/18/2005 VIOL - BUILDING SVCS & SYSTEMS JLANGEJA Violation TFC 605.3- A working space of not less than 30" in width, 36" in depth and 78" in height shall be provided in front of electrical service panels.
01/18/2005 VIOL - BUILDING SVCS & SYSTEMS JLANGEJA Violation TFC 605.4- Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. 1. main studio x 3 2. back room (nw) 3. kitchen
01/18/2005 VIOL - BUILDING SVCS & SYSTEMS JLANGEJA Violation TFC 605.5- Extension cords shall not be a substitute for permanent wiring. 1. main studio x 2 2. kitchen
01/18/2005 VIOL - FIRE PROTECTION SYSTEMS JLANGEJA Violation TFC 901.6- Fire protection systems shall be maintained in operative conditions at all times. Fire extinguisher needs to be recharged.
01/18/2005 VIOL - FIRE PROTECTION SYSTEMS JLANGEJA Violation TFC 906.7- Hand-held portable fire extinguishers shall be installed on the hanger or bracket.