Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T05DV01164
Case Details
Entered Date:
12/01/2005
Applicant:
LLOYD TIM
Description:
FRONT DOOR OFF THE HINGES, BOTH BATHROOM WINDOWS DO NOT CLOSE, ONE IS BROKEN, HOLE IN THE FLOOR NEAR THE TUB AND ONE IN THE HALLWAY.
Outstanding Inspections
Case Number: T05DV01164
Case Status: CANCEL
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: CANCEL
Case Number: T05DV01164
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2006 | INSP - INITIAL CODE ENFORCMENT | MROMERO | Approved | INSPECTION: STEPS FOR ENTRANCE BOW CAUSING TRIP HAZARD NO RAILS 4 STEPS WATER LINE WITH METER NO VIOLATION GAS LINE WITH METER NO VIOLATION AREA ON ON METER SIDE WET FROM PREVIOUS WATER BREAK 50 AMP SERVICE PEDESTAL OK INTERIOR: FRONT DOOR; PANELING MISSING; NOT PROPERLY SEALED (MASTER) EAST BEDROOM: WINDOW (SOUTH) DOES NOT CLOSE PROPERLY CAUSING WATER DAMAGE ON WALL WINDOW (WEST) DOES NOT CLOSE PRPERLY CAUSING WATER DAMAGE ON WALL; DOOR KNOB MISSING SMOKE DETECTOR BROKEN LIGHT FIXTURE-LACKING GLOBE; HAZARDOUSLY MOUNTED ON WALL LOOSE AND FALLING OFF.OUTLETS TEST "CORRECT" COVERS MISSING. BATHROOM: CABINET DOORS FALLING OFF HINGES; TOILET TANK LID BROKEN. TENANTS UNSING STRING TO FLUSH TOILET. LACKING FUNCTIONING WINDOW AND/OR VENT. VENT FOR HEATER MISSING, HOLE IN FLOOR 3" x 8" KITCHEN: VINEL TILE MISSING CAUSING TRIP HAZARD, NO WORKING SMOKE DETECTOR/ OUTLETS TEST "CORRECT". WINDOWS DO NOT CLOSE PROPERLY; WATER DAMAGE TO WALLS PANELING MISSING HALLWAY: LIGHT FIXTURE HANGING EXPOSING LIVE WIRES, PANELING FALLING OFF RAILING AJACENT TO COOLER. NO REQ/VENT FOR COOLER, HOLES IN PANELING 2' x 2' .PANELING ON BATHROOM SIDE SEPERATING FROM STUDS. REAR DOOR: BOWED AND LACKING WEATHER STRIPING 2ND BATHROOM: WINDOW LEAKING, PANELING DOES NOT OPEN OR CLOSE PROPERLY NO GLOBE OVER LIGHT FIXTURE BATH/SHOWER NOT PROPERLY SEALED CAUSING WATER DAMAGE CABINET DOOR FALLING OR BROKEN OFF REAR BEDROOM: DOOR DOES NOT CLOSE PROPERLY AND NO DOOR HANDLE/NO SMOKE DETECTOR PANELING FALLING OFF WALL AND NEED PAINTING HOLES IN WALLS AND LACKING TRIM, HOLES IN CEILING WINDOW DOES NOT FUNCTION PROPERLY FLOOR- HOLE COVERED BY CARPET MISSING COVER PLATE FOR OUTLET COVER PLATE MISSING FOR SUBPANEL FURNACE: WORKING BUT FULL OF DUST- FIRE HAZARD WATER HEATER: NEEDS A REDUCER FOR EXHAUST VENT 3 UNIT VACANT AND UNSECURED W.W.P. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01164
Case Status: CANCEL
Total Completed Case Activity Conditions: 1
| Date | Name |
| 01/06/2006 | CONTACTED BY PHONE |