Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

11/29/2005

Applicant:

DONNA (DEED & NOTE TRADERS

Description:

HEAT HAS NOT BEEN TURNED ON, HAS 3 CHILDREN. LEAK IN KITCHEN WALL. POTENTIAL ELECTRICAL HAZARDS, WIRING IS OLD, AND NEEDS TO BE REWIRED.

Outstanding Inspections

Case Number: T05DV01152
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 25
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - DETACHED STRUCTURES None Not Inspected
VIOL(BL) - FOUNDATION None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
VIOL(BL) - ROOF None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
VIOL(EL) - OTHER None Not Inspected
NPO(PL)-SEWAGE DISPOSAL (SYS) None Not Inspected
VIOL(PL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(PL)-OTHER None Not Inspected
NPO(HC)-NO VENTILATION None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - INSECTS/PESTS None Not Inspected
VIOL(PC) - RODENTS None Not Inspected
NPO - EGRESS None Not Inspected
NPO - SMOKE ALARMS None Not Inspected
12/13/2005 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 12/13/05, VISITED SITE, TOOK PICTURES, MET WITH OCCUPANT BETTY WHO SHOWED ISSUES AS FOLLOWS. LIVING ROOM MISSING PROTECTIVE ELECTRICAL COVER PLATES. FRONT NORTH/EAST BEDROOM, OUTLETS SHOW OPEN GROUND UNDER TEST, DWELLING LACKS WORKING SMOKE DETECTORS. KITCHEN SINK LEAKS GREY WATER WHEN DRAINED, SEWER DRAIN LINE PROBLEM, ONLY LEAKS WHEN DRAINING. HAS 2 SEPERATE SERVICE ENTRANCE LINES LAYING ON FLOOR UNDER KITCHEN CABINET AT THIS TIME BOTH S/E CABLES ARE LAYING IN THE WATER. ELECTRICAL BEHIND STOVE LACKS PROPER CONNECTION, NO RECEPTICLE, HARD WIRED IN. BATH ROOM SOUTH/EAST CORNER HAS BEEN ADDED, FUSE PANEL BOX ON NORTH WALL OF BATH ROOM, WATER LINES ADDED HOT & COLD, ADDITIONAL SEWER CONNECTION FOR SHOWER AND TOILET AND SINK. WATER ON FLOOR, TOILET LEAKS. APPEARS TO BE A WALK IN CLOSET. FLOOR PROTECTIVE COVERING MISSING IN AREAS, RIPED & TORN AROUND TOILET. BATH SINK CONTINOUSLY LEAKS. HALL WAY LIGHT FIXTURE MISSING PROTECTIVE COVER. HALL WAY FLOOR LINOLEUM MISSING TORN AROUND DOOR. ENTRY DOOR HOLLOW CORE HAS HOLE IN BOTTOM RIGHT CORNER. HALL WAY (GUEST) BATH METAL PIECE HAS BEEN INSTALLED IN FRONT WHERE TEMP. CONTROL KNOBS ARE LOCATED WRONG MATERIAL, BATH LIGHT FIXTURE MISSING PROTECTIVE COVER. TUB CONTINOUSLY LEAKS. BED ROOM S/W. 3-PRONG OUTLETS SHOW OPEN GROUND UNDER TEST. PROTECTIVE COVER PLATES MISSING. DOOR MISSING ALL HARDWARE. LIGHT FIXTURE CLOSET MISSING PROTECTIVE COVERING. LIGHT ABOVE WINDOW NOT PROPERLY INSTALLED, USING EXTENSION CORD TO SUPPLY POWER NEEDS TO BE HARD WIRED. WINDOW BROKEN. WINDOW FRAMES PAINTED CLOSED. MISSING VENT AIR DIFFUSER. BEDROOM N/W. DOOR BROKEN. COVER PLATES MISSING. 3-PRONG OUTLETS SHOWING OPEN GROUND. CEILING SHOWS EVIDENCE OF ROOF LEAK. REPAIRS ON INTERIOR STARTED NOT COMPLETED. CLOSET LIGHT FIXTURE MISSING PROTECTIVE COVERING. CARPORT HAS BEEN ENCLOSED. CARPORT HAS EXPOSED RAW WOOD EXPOSED TO ELEMENTS. LAUNDRY FACILITY ROOM HAS BEEN ADDED, WATER LINES, ELECTRIC, 2 OTHER ADDITIONS HAS BEEN ADDED TO SOUTH WEST SECTION OF MAIN STRUCTURE. MAIN STRUCTURE HAS HAD A STAIRWWAY INSTALLED ON SOUTH/EAST SECTION, RISE AND RUNS WRONG, WIDTH IS WRONG. ADDEDED ELECTRICAL CIRCUITS, OPEN EXPOSED CONDUCTORS. ARCHWAY THAT CONNECTS TO ALL UNITS ERECTED WITHOUT PERMIT. 2 OTHER UNITS IN REAR CONNECTED TO FRONT MAIN STRUCTURE BY ROOF & ARCH WAY. ELECTRICAL SERVICE PANEL CONNECTED TO REAR STRUCTURE S/E, DOUBLE LUGGED. SEWER LINES IN REAR ADDED NEW ABS, OPEN, ELERICAL LINE HANGING. ROOF TOP SHOWS WHERE EXPOSED CONDUCTORS. GROUND CONDUCTOR DETERIORATED, LOST EXTERIOR PROTECTIVE COATING. ROOF TOP ELECTRICAL ALL WRONG. DOUBLED LUGGED IN FRONT SERVICE PANEL. ROOF SHOWS EVIDENCE OF CRACKING, NOT COMPLETED FROM ADDITIONS, LEAKING THROUGH TO LIVING SPACE. DOUBLE KEYED DEAD BOLTS INSTALLED ON SECURITY DOOR SCREEN, AND ENTRY DOORS.

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV01152
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/20/2006 INSP - FOLLOW UP CODE ENFORCE JHURD Approved MET W/OWNER JAMES LAYNE AT DNR OFFICE WENT OVER ISSUES FOUND MISTAKE ON CITY JAMES WAS TOLD CASE HAS BEEN CLOSED ON 04/18/06 AFTER THIS WAS BROUGHT TO ATTN. BASICALLY RESTARTED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01152
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
11/29/2005 CONTACTED BY PHONE
03/21/2006 NOTICE OF VIOLATION ISSUED
03/22/2006 VIOLATION CLOSED
10/01/2008 RESEARCH

Documents

File Name Document Type  
T05DV01152 NOV.PDF DOCUMENTS VIEW
T05DV01152 INSPECTIONS.PDF DOCUMENTS VIEW
T05DV01152 CONDITIONS.PDF DOCUMENTS VIEW
NOTES 01-02-07.PDF DOCUMENTS VIEW
NOTES 01-10-07.PDF DOCUMENTS VIEW
NOTES 12-28-06.PDF DOCUMENTS VIEW
NOV 02-05-07.PDF DOCUMENTS VIEW
4-26-07 NOTES,PERMITS+ PG.PDF DOCUMENTS VIEW