Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

11/04/2005

Applicant:

GARCIA CONSTANTINO TR 1/2 & GARCIA

Description:

DOOR LOCKS NOT WORKING, CEILING LEAKS, STRUCTURAL REPAIRS NEEDED.

Outstanding Inspections

Case Number: T05DV01022
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 13
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
VIOL(PL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - SMOKE ALARMS None Not Inspected
11/08/2005 INSP - INITIAL CODE ENFORCMENT WNAVARRO Correction Required VISITED SITE ,TOOK PICTURES,INSPECTED UNIT AND FOUND IN UNIT EXTERIOR LIGHT GLOBE MISSING,FRONT DOOR JAM IS MISSING SOME OF THE WOOD AND WEATHER STRIPPING IS MISSING ALSO,DOOR HINGES ARE LOOSE TO CAUSE HANGING UP WHLE CLOSING. CEILING ABOVE DOOR SHOWS WATER DAMAGE AND SHEETROCK IS WARPED AND TEXTURE IS FALLING OFF. UNIT INSIDE NEEDS TO BE CLEANED DUE TO EGRESS. KITCHEN DRAWERS ARE MISSING,DOORS ARE LOOSE AND FALLING OFF.OUTLETS TO THE SOUTH AND NORTH OF KITCHEN SINK ARE NOT GFCI,THE NORTH OUTLET DOES NOT SHOW OPERATING.RANGE HOOD FILTER IS LOOSE AND HELD UP BY SCREWS,SLIDING GLASS DOOR IS OPENING OR CLOSING PROPERLY AND NEEDS ADJUSTMENT,FRAME COMING APART AND GLASS LOOSE IN FRAME. WEEDS AND TRASH AND DEBRIS IN BACK YARD.EXPOSED TWO FORTY CIRCUIT FOR DRYER OUTLET HAS EXPOSED ROMEX AND IMPROPERLY INSTALLED,DONE WITH OUT PERMITS. BATHROOM LIGHT FIXTURE IS MISSING GLOBE COVER,TILE IN SHOWER STALL ARE FALLING OFF AND WATER IS ENTERING BEHIND TO CAUSE WATER DAMAGE,VANITY SINK FAUCET IS LEAKING AND P-TRAP IS ALSO LEAKING,SINK IS WORN OUT,BATHROOM DOOR JAM HAS BROKEN STRIKER. HOT WATER HEATER AND FURNACE COMPARTMENT SHOWS WATER DAMAGE ON CEILING AND IS WARPED AND TEXTURE FALLING OFF,GLOBE LIGHT COVER IN SAME IS MISSING IN HALL,NEW GAS PIPEING (NO PERMIT) ALSO LACKS PROPER AGA GAS VALVES.FURNACE LACKS PROPER MAINTAINCE. MASTER BED ROOM -HOLE IN WALL FROM DOOR KNOB,DEBRIS,DOOR BROKEN AND NEEDS ADJUSTMENT.HOLE IN SOUTH WEST WALL SCREWED AND TAPED WITH DUCT TAPE.BEDROOM TO THE SOUTH WEST-GLOBE LIGHT COVER IS MISSING. FOUND IN THE SERVICE ENTRANCE TO HAVE DOUBLE LUGGING AT THE NEUTRAL,TOP RIGHT BREAKER IS NOT PROPERLY MARKED,CONNECTION FOR THE DRYER IS OPEN AND EXPOSED ROMEX. FACIA IS ROTTED,EXTERMINATOR CAME OUT ON THE DATES OF OCTOBER FORTH THRU THE SIXTH. TENANT-CHRISTINA-529-2000 EXT-6449

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV01022
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/14/2006 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved VISITED SITE SPOKE W/MGR - MGR CALLED OWNER, OWNER STATED HE HAS BEEN WORKING ON UNITS AND SHOULD BE DONE IN ABOUT TWO WEEKS. WILL F/U IN 2 WKS TO DO FINAL INSPECTION UNITS #1,2,4. ELECTRICAL SVS PANEL WAS INSTALLED AND NEW STOVE INSTALLED IN UNIT #2, TENANT IS BACK IN. ELECTRICAL FINAL WAS APPROVED BY DSD.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01022
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
03/14/2006 CONTACTED BY PHONE
12/09/2005 NOTICE OF VIOLATION ISSUED
03/26/2009 VIOLATION CLOSED

Documents

File Name Document Type  
2005-11-01 240 VOLT OUTLET FOR DRYER.JPG IMAGES VIEW
2005-11-01 BATH TUB TILE TWO.JPG IMAGES VIEW
2005-11-01 BATH TUB TILE.JPG IMAGES VIEW
2005-11-01 BATHROOM LIGHT FIXTURE.JPG IMAGES VIEW
2005-11-01 BATHROOM WALL .JPG IMAGES VIEW
2005-11-01 BED ROOM CLOSET.JPG IMAGES VIEW
2005-11-01 BEDROOM DEBRIS TWO.JPG IMAGES VIEW
2005-11-01 BEDROOM DEBRIS.JPG IMAGES VIEW
2005-11-01 BEDROOM DOOR.JPG IMAGES VIEW
2005-11-01 BEDROOM TWO.JPG IMAGES VIEW
2005-11-01 BEDROOM WALL .JPG IMAGES VIEW
2005-11-01 BEDROOM.JPG IMAGES VIEW
2005-11-01 CARPET APART.JPG IMAGES VIEW
2005-11-01 CLOSET DOOR CASEMENT.JPG IMAGES VIEW
2005-11-01 DOUBLE LUGGED ON SUB-PANEL.JPG IMAGES VIEW
2005-11-01 EXTERIOR LIGHT.JPG IMAGES VIEW
2005-11-01 FACIA 2.JPG IMAGES VIEW
2005-11-01 FACIA.JPG IMAGES VIEW
2005-11-01 FRONT DOOR.JPG IMAGES VIEW
2005-11-01 FURNACE CLOSET .JPG IMAGES VIEW
2005-11-01 GAS VALVE FOR HOT WATER HEATER.JPG IMAGES VIEW
2005-11-01 HOT WATER HEATER AND FLEX CONNECTION.JP IMAGES VIEW
2005-11-01 HOT WATER HEATER.JPG IMAGES VIEW
2005-11-01 INTERIOR CEILING FRONT ROOM.JPG IMAGES VIEW
2005-11-01 INTERIOR FRONT DOOR.JPG IMAGES VIEW
2005-11-01 INTERIOR FRONT ROOM-CEILING.JPG IMAGES VIEW
2005-11-01 INTERIOR HALL LIGHT.JPG IMAGES VIEW
2005-11-01 LAVATORY.JPG IMAGES VIEW
2005-11-01 P- TRAP.JPG IMAGES VIEW
2005-11-01 RANGE EXHAUST FAN.JPG IMAGES VIEW
2005-11-01 ROMEX FOR 240 VOLT DRYER.JPG IMAGES VIEW
2005-11-01 SHEETROCK REPAIR ON BEDRROM WALL.JPG IMAGES VIEW
2005-11-01 SLIDING GLASS DOOR.JPG IMAGES VIEW
2005-11-01 SUB-PANEL 2 .JPG IMAGES VIEW
2005-11-01 SUB-PANEL 3.JPG IMAGES VIEW
2005-11-01 SUB-PANEL FEEDING 240 VOLT DRYER.JPG IMAGES VIEW
2005-11-01 SUBPANEL.JPG IMAGES VIEW
2005-11-01 WASHING MACHINE OUTLET.JPG IMAGES VIEW
2005-11-01 WASHING MACHING TRAY.JPG IMAGES VIEW
2005-11-01240 OULET FOR WASHER.JPG IMAGES VIEW
2005-11-01ADDRESS.JPG IMAGES VIEW
2005-11-01EXTERIOR LIGHT.JPG IMAGES VIEW
2005-11-01SUB-PANEL 4.JPG IMAGES VIEW
N.O.V DOCUMENTS VIEW