Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

09/26/2005

Applicant:

LRN TRUST

Description:

NO LOCKS ON WINDOWS, LEAK IN BEDROOM CEILING, TRIP HAZARDS ON DINING ROOM FLOOR. DISHWASHER DOESN'T WORK, EXHAUST FAN IN BATHROOM DOESN'T WORK. BACK SLIDING DOOR DOES NOT FIT INTO FRAME.

Outstanding Inspections

Case Number: T05DV00764
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00764
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/01/2005 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved MET WITH TENANT BELLE, WENT OVER THE MANY PROBLEMS BELLE FELT SHE WAS HAVING WITH THE OWNER. EXPLAINED THAT I WOULD BE CONDUCTING A THOROUGH MINIMUM HOUSING INSPECTION. BELLE ALLOWED ENTRY. TOOK ME TO THE EXTERIOR REAR YARD, MY FINDINGS ARE AS FOLLOWS. EXTERIOR: 1) OVER ACCUMILATION OF TRASH AND DEBRIS 2) EVES ARE MISSING BIRD BOARD 3) PAINT FLAKING AND PEELING 4) TRIM AROUND SGD DETERIORATING OR MISSING DUE TO LACK OF PAINT. 5) REAR SLIDING GLASS DOOR NOT INSTALLED PROPERLY. SLIDING DOOR GETS DIFFICULT TO PUSH ONCE LEFT OPEN DUE TO FICED PART NOT CORRECTLY INSTALLED. (APPEARS DOOR IS WRONG FOR FRAME.) * FRONT GARAGE TO 2127 FALLING DOW AS POST HAS ROTTED AT THE BASE AND HAS BEEN KICKED AWAY. LEANING APPROXIMATELY 12 ", NO POST BASE OR CONNECTING HARDWARE RAFTERS TO BEAM. INTERIOR FEATURES: 1)FRONT DOOR SAGGIN/ TOO NARROW FOR FRAM, 1/2" GAP BETWEEN DOOR AND JAMB, MISSING A THRES HOLD 2)HALL CLOSET DOORS ARE FALLING OFF AND NEED REPLACING. 3) SOUTHWEST BEDROOM DOOR LACKS A KNOB AND HAS A HOLE IN THE DOOR. 4)BLINDS LACK STICK TO OPEN AND CLOSE. 5)BOTH WINDOWS LACK PROPER LOCKING MECHANISM (CATCH BROKEN OFF) 6)SOUTHWEST BEDROOM WINDOW DOES NOT OPEN. 7) APPEARS ROOF HAS BEEN LEAKING, EVIDENCED BY WATER STAINS ON CEILING 8) SOUTHWEST BEDROOM CLOSET HAS NO FLOORING 9)NORTHWEST BEDROOM CLOSET DOOR IS MISSING 10)NORTHWEST BEDROOM DOOR LACKS STRIKER PLATE 11) NORTHWEST BEDROOM WINDOW WORKS( VERY DIFFICULT FOR ME TO OPEN) 12)KITCHEN CABINET DRAWERS MISSING (2) CABINET FACES 13)KITCHEN WINDOW LACKS PROPER LOCKING MECHANISM. PLUMBING: 1)HALL SINK LACKS A STOPPER 2)TUB MISSING CAULK ON BASE AND SURROUNDING TOP OF TUB 3)IMPROPER CLEARANCE AT HWH 4)MASTER BATH SINK CRACKED 5)RUSTED MASTER BATH SHOWER 6)DISHWASHER IS NOT WORKING, WATER INSIDE. ELECTRICAL: 1)FRONT PORCH LIGHT NO FLUSH TO WALL 2)HALL LIGHT NO COMPLETED, LACKS BULB AND COVER 3)BATH RECEPTICLES NOT GFCI PROTECTED 4)BATH FAN NOT WORKING 5)MASTER BATH OUTLET NOT GFCI PROTECTED 6)MASTER BATH NFAN NOT PROPERLY WORKING, RUNS VERY SLOWLY AND NOT PULLING AIR. 7)ELECTRICAL PANEL SHOWS CONNECT, HOWEVER WIRES ARE NOT PROPERLY COLORED 8)GFCI RECEPTICLE IN KITCHEN NOT GFCI PROTECTED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00764
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
12/14/2005 CONTACTED BY PHONE