Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

09/13/2005

Applicant:

GUERRA HAROLD D & BARBARA A CP/RS

Description:

Gas stove hazzardous- southwest gas shut off

Outstanding Inspections

Case Number: T05DV00663
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00663
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/06/2005 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved VISITED SITE, SPOKE WITH TENANT FREDDI CARILLO, FREDDI MENTIONED THAT SHE WAS PLACED IN UNIT C DUE TO MOLD PROBLEM SHE WAS HAVING IN HER ORIGINAL UNIT, WHICH IS NO LONGER BEING OCCUPIED. MENTIONED THAT SHE MOVED FROM 1ST UNIT TO RECENT UNIT BACK IN JULY. FREDDI WENT OVER ISSUES THAT SHE WAS MOST CONCERNED WITH. HAD COMPLAINED AND SENT A LETTER TO MANAGEMENT COMPANY, BREWER AND CALDWELL, BUT COMPANY HAD DROPPED OWNERS AS A CLIENT DUE OWNER WAS NOT WILLING TO FIX OR PROVIDE FUNDS FOR WHAT PROPERTY MANAGER WAS ASKING TO BE REPAIRED. FREDDI MENTIONED THAT OWNERS SON PETE GUERRA WAS RESPONSIBLE FOR MAKING NECCESARY REPAIRS BUT THAT SHE HAS FELT HARRASSED BY PETE AS PETE FEELS SHE IS PURPOSELY BREAKING THINGS. FREDDI HAD CALLED SW GAS TO CHECK STOVE, 1ST TIME FOUND THE STOVE TO HAVE A GAS LEAK, STOVE WAS REPLACED, AND A 2ND RECEIPT SHOWED 2ND STOVE STILL HAD A GAS LEAK AT THE BASE OF BURNER. AT THIS TIME I EXPLAINED TO FREDDI THAT I WOULD BE CONDUCTING A COMPLETE INSPECTION OF THE UNIT.MY FINDINGS ARE AS FOLLOWS: MECHANICAL: >PROPERLY MAINTAIN COOLER AS PIR FEELS WARM FROM THE REGISTERS. CHECK PADS, PUMP, LOUVERS, SPIDERS, ETC... >RETURN AIR REGISTER LACKS AN AIR FILTER. ELECTRICAL: >KITCHEN/DININGROOM 3 SWITCH BOX HAS ONE BROKEN SWITCH. REPLACE >REFRIGERATOR RECEPTICLE LACKS A COVER PLATE. >MASTER BEDROOM LIGHT SWITCH LACKS COVER PLATE. >MASTER BATH GFCI RECEPTICLE NOT PROPERLY MOUNTED IN THE WALL. >HALL BATH, SWITCH, COVER PLATE, DOES NOT COVER OPENING >HALL RECEPTICLE LACKS COVER PLATE >RECEPTICLE WEST BEDROOM, WEST WALL NOT PROPERLY MOUNTED IN WALL >COOLER SWITCH HAS THE HIGH AND LOW IMPROPERLY WIRED BACKWARDS. >LAUNDRY ROOM LIGHT FIXTURE LACKS BULB AND PULL CHAIN IS TOO SHORT TO REACH. PLUMBING: >DISHWASHER NOT WORKING AND HAS NOT SINCE SHE MOVED INTO THAT UNIT. >MASTER BATH SHOWER FAUCET IS NOT PROPERLY MOUNTED, LEAKS WHEN IN USE. INTERIOR FEATURES: >KITCHEN COUNTER TOP IS DE TERIORATING EVIDENCED BY LAMINATE OFF THE FACE OF COUTER TOP AND WOOD UNDERLAYMENT CHAFFING. >BOTH SLIDING GLASS DOORS FRONT AND BACK HAVE BEEN INSTALLED INCORRECTLY WITH THE SOLID GLASS PANE ON THE INSIDE AND SLIDING DOOR ON THE OUTSIDE ALLOWING SLIDING DOOR TO BE LIFTED OUT. >OUTSIDE LAUNDRY ROOM DOOR AND JAMB ARE DETERIORATING, LACKS GRILLE FOR VENT. AFTER COMPLETING INSPECTION I SPOKE WITH PETE GUERRA WHO MENTIONED AGAIN THAT HE FELT TENANT WAS INTENTIONLY BREAKING THINGS. PETE ALSO MENTIONED THAT THE SALE OF THE UNIT HAD GONE THRU YESTERDAY, AND THAT HIS FATHER WAS NO LONGER THE OWNER. ASKED IF HE NEW OWNERS NAME, HE SAID NO BUT WOULD HAVE THE INFORMATION LATER AND BRING THAT TO THE OFFICE. PETE CAME TO THE OFFICE FOR A COPY OF THE INSPECTION AND AT THAT TIME GAVE ME THE NEW OWNERS NAME (KYLE MARKTARIAN 275-7175). I TRIED TO MAKE CONTACT WITH MR MOHKTARIAN TO VERIFY, RECEIVED VOICEMAIL, LEFT MESSAGE TO PLEASE CONTACT WITH CONTACT NUMBERS. PICTURES WERE TAKEN AT TIME OF INSPECTION.
11/14/2005 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved VISITED SITE, KNOCKED ON DOOR, RECEIVED NO ANSWER.WENT TO UNIT B FOUND WORKER DALE MAKING REPAIRS TO UNIT B, ASKED DALE IF HE WAS FAMILIAR WITHUNIT C, DALE SAID HE DID NOT DO THE WORK BUT KNEW THAT ALL REPAIRS HAD BEEN COMPLETED IN THAT UNIT EXCEPT FOR TWO ITEMS, REPAIRING THE SLIDING GLASS DOORS, AND REPAIRING THE COUNTER TOPS. DALE MENTIONED THAT HE WAS SUPPOSE TO MEASURE UP THE COUNTER TOPS SO THAT NEW TOPS COULD BE INSTALLED. DALE ALSO MENTIONED THAT MAKING CONTACT WITH THE TENANT HAD BEEN DIFFICULT AND I AGREED. SO I WROTE TENANT A LETTER ASKING SHE MAKE CONTACT WITH DALE SO THAT HE COULD GO IN AND MEASURE UP FOR NEW TOPS SO THAT WORK COULD BE COMPLETED AND CASE CLOSED. TAPED LETTER TO FRONT SLIDING GLASS DOOR. RECEIVED A CALL BACK FROM FREDDIE CARRILLO WHO MENTIONED THAT SHE NEVER SAW DALE AT THE COMPLEX. I EXPLAINED THAT HE WAS USUALLY THERE FROM 8:00 TO 4:00, TO PLEASE KEEP AN EYE OPEN SO THAT REPAIRS CAN BE COMPLETED AND CASE CLOSED. NO PICTURES WERE TAKEN.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00663
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
10/06/2005 CONTACTED BY PHONE
02/06/2006 VIOLATION CLOSED