Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

09/09/2005

Applicant:

FAULKNER CHRISTOPHER K

Description:

SEPTIC BACKUP

Outstanding Inspections

Case Number: T05DV00641
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00641
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/13/2005 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE, MADE CONTACT WITH TENANT. INFORMED HER DNR RECEIVED COMPLAINT REGARDING EXTERIOR SEWER CONNECTION WERE ALLOWING RAW SEWAGE ON TO PROPERTY. TENANT RESPONDED SEWAGE PROBLEM HAS BEEN ADDRESSED. INFORMED TENANT OF SERVICES PROVIDED BY DNR TO ACCESS STRUCTURES FOR HEALTH AND SAFETY ISSUES AND IF SHE WOULD ALLOW ENTRY INTO STRUCTURE. TENANT RESPONDED YES. ENTERED UNIT AND CHECKED FOR MIN. HOUSING ISSUES AND ARE AS FOLLOWS: FIRE SAFETY- 1. STRUCTURE LACKS REQUIRED SMOKE DETECTORS ELECTRICAL- TEST EQUIPMENT WAS USED ON INTERIOR RECEPTACLES. 1. 1- RECEPTACLE IN LIVING ROOM TSTED SHOWED REVERSED HOT NAETURAL 2. BREAKER PANEL ENCLOSURE IS INSIDE WOOD CABINET, SEVERAL ELECTRICAL CONDUCTORS ARE NOT IN REQUIRED CONDUIT. APPEARS TO BE WORK WITHOUT PERMITS. 3. LACKING REQUIRED GFCI IN KITCHEN AND BATHROOM. 4. ADDITIONAL CIRCUIT ON EXTERIOR ENTERING WHAT APPEARS TO BE SHED ENCLOSURE IS NOT IN REQUIRED CONDUIT. TENANT DID NOT HAVE KEY TO LOCKED EXTERIOR DOOR LEADING INTO ENCLOSURE HOUSING HOT WATER HEATER. PLUMBING- 1. BATHROOM SINK FAUCET WAS LEAKING. ALL OTHER FIXTURES WERE IN GOOD WORKING ORDER. 2. EXTERIOR VENT DOES NOT EXTEND ABOVE ROOF LINE. MECH SYS- 1. HOT WATER HEATER WAS NOT ACCESSABLE DUE TO PAD LOCK ON DOOR. INTERIOR FEATURES- ALL WALLS, FLOORING, CEILING IN GGOD SHAPE. EXTREMELY WELL KEPT. WEATHER STRIPING- NO ISSUES WERE FOUND ACCESS CONTROL- NO ISSUES WERE FOUND, ALL WINDOWS LOCKS ARE IN GOOD WORKING ORDER. COOLER- NO ISSUES FOUND. W/O/P- APPEARED CAR GARAGE HAS BEEN CONVERTED INTO HAPITABLE SPACE WITH WATER AND ELECTRIC. STRUCTURE HAS NO METER. DOES HAVE ELECTRICAL SUBPANEL INSIDE HOUSE. ACCORDING TO TENANT, ELECTRICAL BILLING IS FOR FRONT HOUSE, SAME FOR WATER. ELECTRIC AND WATER ARE INCLUDED IN RENTAL. STRUCTURE LACKS OWN WATER SHUT OFF. WILL CHECK DSD RECORDS FOR APPROVED PLANS AND PERMITS. EXTERIOR FEATURES- NO ISSUES WERE FOUND OTHER THAN 2 FOOT SECTION CONTAINING SOME WOOD ROT ON NORTHEAST END. NEAT IS SUPPLIED BY BASE BOARD HEATER IN KITCHEN AREA. PICTURES WERE TAKEN. NOV PENDING RESEARCH AT DSD.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00641
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
01/31/2006 CONTACTED BY PHONE
11/02/2005 NOTICE OF VIOLATION ISSUED
06/05/2007 VIOLATION CLOSED
12/28/2005 RESEARCH
11/07/2006 CITATION ISSUED 9/13/05
03/02/2007 CITATION REISSUED

Documents

File Name Document Type  
CITATION_03.02.07.PDF DOCUMENTS VIEW
CORRESP 5-21-07.PDF DOCUMENTS VIEW
CIVIL MOTION DOCS 5-21-07.PDF DOCUMENTS VIEW
CORRESP 5-21-07.PDF DOCUMENTS VIEW
CORRESP 2-21-07.PDF DOCUMENTS VIEW
FAXED INVOICES 5-21-07.PDF DOCUMENTS VIEW
CITATION 4-10-07.PDF DOCUMENTS VIEW