Case: T05DV00561
Case Details
Entered Date:
08/08/2005
Applicant:
DEEB GEORGE E & MATTHEWS DIANE M JT/RS
Description:
TICK, FLEA, AND RODENT INFESTATIONS
Outstanding Inspections
Case Number: T05DV00561
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00561
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2005 | INSP - INITIAL CODE ENFORCMENT | MROMERO | Approved | PANEL HAS BEEN REPLACED DUE TO CONVERSATION WITH "CASEY" AT DEEBEE PROPERTIES. BUT NO PERMITS AND NO TO CODE. 60 AMP FEEDING 3/20 AMP AND 2 OUTSIDE SUBPANELS. SERVICE PANEL INSTALLED IN A HAZARDOUS MANER, HOLES IN PANEL NOT WATER TIGHT. SCREWS MISSING FOR COVER, DEED PLATE. GROUND ROD CUT, MIXING CONDUCT WITH P.V.C AND CALUINIZED PIPING. LOOSE CONNECTIONS, WIRING HANGING, NOT PROPERLY CONNECTED. MIXING WIRES IE. RED FOR GROUND, BLACK TO BREAKER. MIXING STYLE STYLE AND MAKES OF BREAKERS. PANEL LACK BOARDING. PANEL IS WORK WITHOUT PERMITS, HAZARDOUSLY AND IN A UNSAFE CONDITION. SUBPANEL ON EASTSIDE OF PROPERTY 1 NOT CONNECTED, NEEDS TO BE PERMITTED, NO LISTING. 2ND SUB 2/20 FUSES WITH GROUND TWISTED TOGETHER, IMPROPER WIRE CONECTION. ROMEX HANGING AND STRUNG ACROSS, WILL NOT PROPERLY ANCHORED OR PROTECTED. 12/2 ROMEX AS NEEDED. SHED: 20 AMP BREAKER IN SUBPANEL WITH ADDED CIRCUITS FOR LIGHTS AND OUTLETS, HAZARDOUS WIRING. NO DEAD PLATES AND IN A HAZARDOUS LOCATION, OPEN SPLICES. INTERIOR: NO SMOKE DETECTORS IN LIVING ROOM, KITCHEN STOVE NO SHUT OFF VALVE FOR STOVE. NO VENT HOT AND NEUTRAL REVERSE IN KITCHEN BEDROOM: NO SMOKE A2 ROOM IN BACK POSIBLE BUILT WITHOUT PERMITS, EVIDENCE BY CEILING HEIGHT BELOW 7'. HOT WATER IN ROOM WITH CARPET UNDER IT (FIRE HAZ) NOT IN A INCLOSER. ROMEX COMING FROM EXTERIOR SPLICED WITH RECEPTACLE. IMPROPER WIRING METHOD AND MATERIALS. ROMEX INSTALLED IN A RACEWAY SYSTEM/ ROMEX NO FEEDER FOR SUBPANEL. SHOULD BE BRANCH CIRCUIT. USING UNAUTHORIZED FOR ELECTRICAL EQUIPMENT MATERIAL, INTERIOR AND ON TOP. USING SHEET METAL ON TOP OF PANEL BOARD, FOR RAIN TIGHT. USING P.V.C AS ELETRICAL RACEWAY. OPEN KNOCKCUT. IMPROPER WIRE ENTRIES. IMPROPER OVER CIRCUIT PROTECTION OF RENDUCTORS. CONDUCT CONDUCTOR OVERFILL EXTENDED. CONDUIT SIZE INCOMPATABLE WITH CONDUCTOR SIZE. BOND CONTINUINITY IMPAIRED DUE TO IMPROPER CONDUIT CONNECTION (OVERSIZED KNOCKOUTS WITHOUT PROPER FITTINGS) NO PROPER GROUND ELETROD SYSTEM VERITIABLE. NEAT AND WORKMAN LIKE MANOR. CONSOLIDATE ELECTRICAL EQUIPMENT OR PROVIDE PLAN/ RAISER POAGRON OR PANEL SCHEDULE |
| 12/06/2005 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | FOLLOW UP INSPECTION. TENANT AT HOME. UNANNOUNCED VISIT. *TICKS STILL PRESENT IN CARPET AND KITCHEN AREA. >SERVICE PANEL UPGRADE COMPLETED TO 100 AMPS. PERMITS IN FINAL STATUS. >SMOKE DETECTORS ARE IN PLACE. >GAS SHUT OFF VALVE FOR STOVE REPLACED. *PLUMBING PERMIT NOT FINALED IN PERMITS PLUS. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00561
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 11/08/2005 | CONTACTED BY PHONE |
| 10/07/2005 | NOTICE OF VIOLATION ISSUED |
| 02/06/2006 | VIOLATION CLOSED |