Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

07/29/2005

Applicant:

WATTERSON PETE R & KAY W JT/RS

Description:

UNSTABLE STAIRS- TNEANT FELL THROUGH STEP

Outstanding Inspections

Case Number: T05DV00532
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00532
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/16/2005 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved IN ROUTE TO INSPECTION I TRIED TO MAKE CONTACTWITH BOTH TENANT AND OWNER, RECEIVED VOICEMAIL FOR BOTH CALLS, LEFT MESSAGES FOR TENANT TRUDY WELLS, AND FOR OWNER MR. WATERSON EXPLAINING THAT THE CALL WAS CONCERNING THE BALCONY AND STAIRWAY AT THE PROPERTY OWNED BY MR WATERSON, ASKED THAT THEY PLEASE CONTACT, LEFT CONTACT NUMBERS. VISITED SITE, TOOK PICTURES, KNOCKED ON DOOR OF UNIT B, RECEIVED NO ANSWER. WHILE ON SITE I INSPECTED THE STAIRWELL AND BALCONY FOUND NEW STEPS HAD BEEN PUT ONTO THE STAIRWAY AS WELL AS NEW RISERS. STAIRS CONSISTED OF (2) 2 X 6 SCREWED TO 2 X6 BLOCKS BOLTED OR LAGGED WITH (3) 3" LAGS, BLOCKS WERE INSTALLED ON EITHER END, NEW RISERS WERE NAILED TO THE 2 X 6 BLOCKS. PARTS OF HAND RAILING HAD ALSO BEEN REPLACED. CHECKED LANDING, 4 OUTSIDE PERIMETER PCS CONSISTED OF 2 X 10 RAFTERS OR FLOOR JOISTS, INTERIOR JOISTS WERE 2 X 4.PLYWOOD ON LANDING APPEARED TO BE 1/2". STAIRS STRINGERS AND 4 X 4 SUPPORTS SAT DIRECTLY ONTO OR INTO CONCRETE FLOOR. MY OPINION, AFTER VIEWING MANY VIOLATIONS WAS THAT THE STAIRS WERE NOT BUILT TO CODE AND PROBABLY NOT PERMITTED.
11/14/2005 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved VISITED SITE, TOOK PICTURES. UPON ARRIVAL FOUND WORKERS FROM MISSION STEEL COMPLETING SOME SPOT WELDS ON THE STEEL STAIRS DUE TO A CALL BACK AND WERE PREPARING TO DO THE TOUCH UP PAINTING. SPOKE WITH VICTOR WHO MENTIONED THAT STAIRS HAD BEEN BUILT AND COMPLETED ABOUT 2 WEEKS AGO AND THAT THE INSTALATION TOOK PLACE SOMETIME LAST WEEK. WILL CHECK PERMITS PLUS TO SEE IF PERMIT HAS BEEN FINALED. TOOK PICTURES OF ALL ANCHORING OF STAIRS TO THE CONCRETE LANDING AND METAL POSTS TO CONCRETE, AND THE STAIR TO POST ATTACHMENTS. WORKAPPEARS TO BE WELL DONE AND TO CODE. SPOKE WITH OWNER PETE WATTERSON WHO ALLOWED ENTRY TO REAR PORCH AND FOUND THAT ALL CONNECTING PORCH HARDWARE HAD BEEN INSTALLED. FOUND PERMITS HAD BEEN SECURED THRU DSD. COMPLIANCE, CASE CLOSED!!

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00532
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
07/29/2005 CONTACTED BY PHONE
08/22/2005 NOTICE OF VIOLATION ISSUED
11/17/2005 COURT ORDERED ABATEMENT
11/17/2005 VIOLATION CLOSED