Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

06/30/2005

Applicant:

BERT COUVRETTE

Description:

COMPLAINT: COOLING

Outstanding Inspections

Case Number: T05DV00465
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
06/27/2005 INSP - INITIAL CODE ENFORCMENT HLOPEZ Correction Required VISITED SITE AND MET WITH THE TENANT. TALK WITH THE TENANT AND THE TENANT AND THE LANDLORD HAD AN AGREEMENT TO DO REPAIRS. TENANT WAS EVASSIVE ALSO ON WHAT CAUSE DECISSION TO MOVE. TENANT WAS GIVEN A NOTICE TO MOVE AND WILL VACATE AT THE END OF THE MONTH. DID DO INSPECTION AND FOUND SEVERAL MIN. HOUSING ISSUES AS FOLLOWS: ELECTRICAL - 1. COOLER AND ROOF TOP FURNACE ELECTRICAL DISCONNECT DOESN'T HAVE THE REQUIRED 3' CLEARANCE FOR WORKING ON SERVICE, 2. ILLEGAL SLICE ON ELECTRICAL CONDUCTOR FOR COOLER, 3. DEAD FRONT PANEL MISSING ONE BLANK COVER, 4. EXTERIOR RECEPTICAL BY DISCONNECT NOT GFCI OR WEATHER PROTECTED, 5. GFCI LACKING AT KITCHEN AND BATHROOM, 6. INTERIOR HAS 2 PRONGS RECEPTACLES AND APPEARS STRUCTURE ELECTRICAL SYSTEM HAS BEEN MODIFIED WITH 3 PRONGS RECEPTACLE WITH MECHANICAL GROUND HAVE BEEN INSTALLED, CHECK FOR PERMITS, 7. EXTERIOR LIGHT FIXTURE HAS BEEN REMOVED AND HAS EXPOSED ELECTRICAL CONDUCTOR, CONDUCTOR ARE TAPED. WORK WITH OUT PERMITS -- PORCH APPROX. 10' X 12' HAS BEEN ATTACHED TO MAIN STRUCTURE. IMPROPER POST BRACKETS AND UNDERSIZE BEAMS. COOLER IS WORKING BUT IS IN A DETERIORATED, DELAPIDATED CONDITION, WATER PAN IS SEVERLY RUSTED OUT, RUBBER SHEATING HAS BEEN PLACED INSIDE WITH 2ND LARGER PAN UNDERNEIGHT. COOLER DUCT RUNS IN FRONT OF ELECTRICAL DISCONNECT AND APPEARS THAT CFM'S ARE NOT ADEQUITE. COOLER NOT MOUNTED ON APPROVAL STANDS. PLUMBING -- 1. KITCHEN SINK VENT DOES NOT EXTENT ABOVE ROOF LINE, 2. STRUCTURE LACKS GAS SERVICE AMD SOUTHWEST GAS HAS PINNED BOTH METERS. TENANT STATED THAT 2-STRUCTURES ARE ON SAME LINE AND SOUTHWEST GAS HAS TURNED OFF SERVICE, 3. NO ACCESS TO WATER HEATER, WATER HEATER IS ENCLOSED NEXT TO STOVE, UNABLE TO CHECK CONNECTORS AND TPR VALVE WITJ DRAIN LINE, 4. KITCHEN FAUSCET LEAKS, 5. MODIFIED WATER SUYPPLY SYSTEM POSSIBLE WITH OUT PERMITS, WATER LINE IN CLOSET, 6. BEE INFESTATION. BEE'S ARE ENTERING THROUGH 1" HOLES AT SOUTH WALL. TENANT STATED HE WITNESS A LARGE AMOUNT OF BEE'S COVERING AN AREA APPROX. 20" INDIAMETER. BEE'S WERE FOUND ENTERING STRUCTURE. FIRE SAFTY-- STRUCTURE ARE LACKING REQUIRED SMOKE DETECTORS. PICTURES WERE TAKEN, TENANT STATED THAT AZTEC HEATING AND COOLING DID DO AN ACCESSMENT OF THE ROOF TOP FUIRNACE AND TENANT WILL PROVIDE DNR INSPECTOR WITH DOCUMENT STATING HEAT CHAMBER IS DEFECTIVE. DID ISSUE N.O.V. FOR BEE'S INFESTATION AND HAND DELIVERED NOTICE TO TENANT. SPOKE WITH THE OWNERS WIFE/GIRLFREIND STATING TENANT WAS GIVEN AN EVICTION NOTICE APPROX. 2-WEEKS AGO FOR NONE PAYMENT OF RENT. INFORMED HER MIN. HOUSING VOILATION WERE FOUND AND WILL BE RECEIVING N.O.V. FOR ISSUES FOUND. DNR INSPECTOR STATED THERE IS A BEE INFESTATION AND WILL REQUIRE A PEST CONTROL COMPANY TO REMOVE INFESTATION WITH-IN 3-DAYS DUE TO FINDING BEE'S IN THE INTERIOR OF STRUCTURE WITH ONE FOUND INSIDE THE BATHROOM AREA. KALVAIN STATED SHE WILL HAVE BEE ISSUE ADDRESS THIS WEEKEND. N.O.V. WAS ISSUED AND HAND DELIVERED TO TENANT.
07/21/2005 INSP - FOLLOW UP CODE ENFORCE RVIDAL Correction Required WENT TO SITE AND UNIT IS VACANT AND SECURED. CALLED MAINTENCE PHONE NUMBERS GIVEN BY PHONE MESSAGE AND TALK TO SUSAN AND NORM. I WAS TOLD THAT I NEEDED TO TALK TO BERT WHICH WAS OUT OT TOWN AND WILL BE BACK ON MONDAY. THEY WERE NOT SURE OF REPAIRS BEING DONE. WILL CHECK ON TUESDAY 7-26-05 BY PHONE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00465
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
08/10/2005 CONTACTED BY MAILING
07/29/2005
08/10/2005 CONTACTED BY FAX