Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

06/01/2005

Applicant:

DIXON WILLIAM H & DIXON BOBBY RAY

Description:

COMPLAINT RE: RMIN HOUSING- TPD CALL OUT RE: SUB-STANDARD LIVING CONDITIONS.

Outstanding Inspections

Case Number: T05DV00404
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00404
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/17/2005 INSP - INITIAL CODE ENFORCMENT RSALDATE Approved -TPD SCOT HOPPER - SEARCH WARRANT. - OWNERS: HENRY MANUEL DIXION, HENRY MARTIN DIXON. - 3 YRS NO RUNNING WATER FROM ADA CRIME TIP. INSPECTION: - HALLWAY CEILING PATCHED NEEDED TO FINISH. - REAR DOOR HAS DOUBLE KEY LOCK ON IRON SCREEN DOOR, ALSO FRONT DOOR. - BROKEN WINDOW IN BEDROOM. - LOCK & HASPS ON 2-BEDROOM DOORS. DETERIORATED BED DOORS, NO HARDWARE. - USING CANDLES FOR LIGHT. SMOKE STAIN ON CEILING IN 2- BEDROOMS. - BATHROOM DOOR KICKED IN. - HALL NEXT TO BATHROOM KICKED IN. - ATTEMPTING TO PARTITION A EFFICIENCY FROM MAIN HOUSE. NO KITCHEN & NO BATHROOM, DOUBLE KEY. - HOT WATER HEATER RIGGED IN - ELECT. NEED PERMITS INCLUDE LINES. - 2 -REAR PORCHES W/O PERMITS - INCORRECT POT & BEAMS. - COOKING OUTSIDE. - DETACHED PORCH AT REAR, NO PERMITS - ELECTRICAL. - ELECT. METER RED TAG - XH 589975. USING EXTENSION CORD TO EAST NEIGHBOR.
12/23/2005 INSP - FOLLOW UP CODE ENFORCE JORTA Approved HOUSE RE-OCCUPIED-POSTING VIOLATION. Made an inspection with police escort, Officer W. Kaderly (sargeant). Through my investigation at the site and in the office, there has been no real progress whatsoever other than the dumpster being used in two different occasions. There has been no permits obtained at all per the requests on the notice of violation. The time period on the violation has long expired. Add this to the fact that people were in fact are living here without any utilities ie. sanitation, lighting and heat, does pose an imminent danger of a hazard when a substitute for the above is assumed. I called the sister of William Dixon and Bobby Rae Dixon (the tenants and other 2 owners) Betty Howard to see if she could take them in, and the answer was no. I called the social worker Kay Smith to assist me in providing temporary shelter for the two individuals and she said she would be contacting the Salvation Army and she would contact Betty or the police to transport William and Bobby to the shelter. I called the board-up contractor Bathcrest, but they would not answer their phone, I then re-posted the property at the front entry wall and at the fence. Photos taken and police notified of arrest options. I chained and padlocked the two gates and attempted to call Bathcrest again. Again no answer. Came into office and finally contacted Bathcrest and I gave them (Don) very specific directions as to what I needed to secure the property. A) Request a police escort. B) Beware of two dogs. and board-up as follows: WEST SIDE; (1) 4x2 window SOUTH SIDE; (1) wrought iron door -- screw striker flange to frame. EAST SIDE; none. NORTH SIDE; (1) 36" french door and (1) wrought iron door--screw striker flange to frame. Finally police are looking out and this will be alright if this is done Saturday morning in the earlyest possible time.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00404
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 9
Date Name
06/01/2005 CONTACTED BY PHONE
07/13/2005 CONTACTED BY MAILING
06/01/2005 NOTICE OF VIOLATION ISSUED
06/01/2005 COURT ORDERED ABATEMENT
05/29/2007 VIOLATION CLOSED
01/17/2006 Police/possible breach, email received:
11/28/2006 TPD CALLED
11/29/2006 CALL-BACK, WILLIAM DIXON
11/30/2006 CONTACTED T.P.D.

Documents

File Name Document Type  
2007-02-16 001 FRONT AREA, WINDOW REPAIRED. .JPG IMAGES VIEW
2007-02-16 002 WEST PORCH REMOVED. .JPG IMAGES VIEW
2007-02-16 003 SOUTH PORCH REMOVED. .JPG IMAGES VIEW
2007-02-16 004 SOUTH PORCH AREA. .JPG IMAGES VIEW
2007-02-16 005 ONE WINDOW LEFT AT EAST SIDE. .JPG IMAGES VIEW
2007-02-16 006 YARD WITH SHED GONE. .JPG IMAGES VIEW
2007-02-16 007 SHEDS REMOVED. .JPG IMAGES VIEW
2007-03-12 007 NEW PLUMBING. .JPG IMAGES VIEW
2007-03-12 008 NEW WATER HEATER BEING INSTALLED. . IMAGES VIEW
DIXON.TXT DOCUMENTS VIEW
PUEBLO VISTA.PDF DOCUMENTS VIEW
SKMBT_75006120610320.PDF DOCUMENTS VIEW
NOTES OF 120706 .PDF DOCUMENTS VIEW
NOTICE OF VIOLATION WITH NEW TIME FRAMES .PDF DOCUMENTS VIEW
SUMMARY OF CORRECTIONS NEEDED .PDF DOCUMENTS VIEW
CORRESPONDENCE 12-07-06.PDF DOCUMENTS VIEW
NOV 12-19-06.PDF DOCUMENTS VIEW
2005-07-25 001.JPG None VIEW
2005-07-25 002.JPG None VIEW
2005-07-25 003.JPG None VIEW
2005-07-25 004.JPG None VIEW
2005-07-25 005.JPG None VIEW
2005-07-25 006.JPG None VIEW
2005-07-25 007.JPG None VIEW
2005-07-25 008.JPG None VIEW
2005-07-25 009.JPG None VIEW
2005-08-11 001 DOUBLE CYLINDER KEYLOCK.JPG None VIEW
2005-08-11 002 PULLED RECEPT. IN FAM RM. LOOKS OR None VIEW
2005-08-11 004 FAM. RM. OTHER VIEW.JPG None VIEW
2005-08-11 005 PART OF FAMILY ROOM. .JPG None VIEW
2005-08-11 006 STANDARD RECEPTACLE 2-WIRE.JPG None VIEW
2005-08-11 008 KITCHEN AREA.JPG None VIEW
2005-08-11 009 BATHROOM ENTRY.JPG None VIEW
2005-08-11 011 FURNACE ROOM AS CLOSET.JPG None VIEW
2005-08-11 012 FURNACE ROOM. GREEN TAPE AS DUCT T None VIEW
2005-08-11 013 BATHROOM.JPG None VIEW
2005-08-11 014 SHOWER.JPG None VIEW
2005-08-11 015 HOLE IN WALL. GASLINE REPAIR..JPG None VIEW
2005-08-11 016 HALLWAY.JPG None VIEW
2005-08-11 017 INTERIOR VIEW.JPG None VIEW
2005-08-11 018 INTERIOR VIEW.JPG None VIEW
2005-08-11 019 PREVIOUS POSTING.JPG None VIEW
2005-08-11 020 PREVIOUS POSTING FROM RICK.JPG None VIEW
2005-08-11 023 LIGHT FIXTURE .JPG None VIEW
2005-08-11 024 SERVICE EQUIPMENT AREA.JPG None VIEW
2005-08-11 025 WATERHEATER NEEDING SEALTITE OR FLE None VIEW
2005-08-11 026 AN AREA AT THE SOUTH PORCH.JPG None VIEW
2005-08-11 028 SOME OF FACIA BOARD.JPG None VIEW
2005-08-11 029 WATER HEATER JUNCTION BOX ABOVE ROO None VIEW
2005-08-11 030 WINDOW LACKING.JPG None VIEW
2005-08-11 031 ENTRY LIVING ROOM.JPG None VIEW
2005-08-11 033 FRONT DOOR ENTRY.JPG None VIEW
2005-08-11 035 WEST PORCH WHERE WATER HEATER IS NO None VIEW
2005-08-11 036 WILLIAM DIXON STATES THAT HE IS IN None VIEW
2005-08-11 037 MORE ARTICALS ABOUT YARD.JPG None VIEW
2005-08-11 038 SOUTH PORCH OF QUESTIONABLE DESIGN. None VIEW
2005-08-11 039 DEBRIS AND TRASH AT THE WEST SIDE.J None VIEW
2005-08-11 040 THE YARD CLUTTER.JPG None VIEW
2005-08-11 041 ROOF JOIST .JPG None VIEW
2005-08-11 043 CONDITION OF CEILING JOIST .JPG None VIEW
2005-08-11 044 OTHER VIEW OF STORAGE.JPG None VIEW
2005-08-11 045 STORAGE ROOM WITHIN THE SHED.JPG None VIEW
2005-08-11 046 OLD WORK SHED.JPG None VIEW
2005-08-11 047 AN ACCUMILATION OF BUILDING MATERIA None VIEW
2005-08-11 050 YARD CLUTTER.JPG None VIEW
2005-08-11 051 STORAGE HOUSE.JPG None VIEW
1637 W. PUEBLO VISTA NOTICE OF VIOLATION.PDF None VIEW