Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

04/18/2005

Applicant:

POWELL KENNETH H

Description:

COMPLAINT RE: MIN HOUSING- LIVING CONDITIONS.

Outstanding Inspections

Case Number: T05DV00286
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00286
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/18/2005 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE ON INITIAL INSP. MET WITH OFFICER THCHIHA GARRODO FROM TPD & PROPERTY MANAGER WALKED STRUCTURE, PROPERTY HAS 3-STRUCTURES, 1-MAIN STRUCTURE 1-SECONDARY STRUCTURE & 2 GARAGES, 1-STRUCTURE NOT SECURED, SECONDARY STRUCTURE WAS FOUND WITH NORTHSIDE DOOR OPEN. STRUCTURE ARE VACANT AT THIS TIME BUT DO HAVE ELECTRICAL, GAS & WATER AVAILABLE. SEVERAL ISSUES NEED TO BE ADDRESSED ON EXTERIOR OF MAIN STRUCTURE & REST OF ON SITE BUILDINGS. ELECTRICAL SYSTEM: 1) EXISTING ELECTRICAL SERVICE-60 AMP, SERVICE IS OUTDATED & LACKS WEATHER PROTECTION. 2) 60 AMP SERVICE RUNNING BOTH STRUCTURES, SECONDARY STRUCTURES APPEARS TO BE CONNECTED UPGROUND, NO SERVICE DISCONNECT ON EXTERIOR OF SECONDARY STRUCTURE. 3) EXTENTION CORD BEING USED TO PROVIDE POWER TO 2ND GARAGE IS SPLICED & IS IN A DETERIORATED STATE, INSULATION IS CRACKED, ELECTRICAL CONDUCTORS CONNECTION LACK PROTECTIVE WIRE NUTS. 4) ILLEGALLY SPLICED ELECTRICAL CONDUCTORS NORTHSIDE OF STRUCTURE. ROOF: 1) BOTH STRUCTURES ROOFING MATERIAL HAVE DETERIORATED INTO A DILAPIDATED STATE, ROOFING IS CRACKED & FALLING APART. STRUCTURAL: 1) MAIN STRUCTURES WALLS SHOW STRESS CRACK THROUGHOUT, SOME CRACKS AS WIDE AS 1/4 INCH, SECTION OF PLASTER HAS BROKEN AWAY FROM WALLS. TRASH & DEBRIS: LARGE AMOUNTS OF DRYED COMBUSTIBLE VEGITATION THROUGHOUT PROPERTY. ACCESSORY STRUCTURE: WOOD FENCING IN A DETERIORATED & DILAPIDATED STATE & LACKING PAINT COVER FOR WEATHER PROTECTION, BOARDS ARE BROKEN, SPLITTERED & FALLING APART. PICTURES WERE TAKEN, N.O.V. WAS ISSUED & POSTED. INFORMED PROPERTY MANAGER TO CONTACT TOM INGRAM FOR POSSIBLE DEMO. TOM WAS CONTACTED & WILL BE MAKING ARRANGEMENTS FOR DEMO PROCESS. ALSO CONTACTED WAS ZONING (B.J.) PROPERTY IS R2 ZONING & WILL BE ALBE TO ACCEPT MANUFACTURED HOMES. WILL HAVE TO SUBMIT PLANS FOR REVIEW IF TRAILERS ARE PLANNED FOR PROPERTY. DUE TO LARGE AMOUNTS OF COMBUSTIBLE DRYED VEGETATION ABATEMENT TIME ALLOWED WILL BE 3 WEEKS, ALL OTHER VIOLATIONS WILL BE 30 DAYS FOR ABATEMENT.
09/09/2005 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE, STRUCTURE IS STILL VACANT AND SECURED AT THIS TIME. NO BOARDS ON WINDOWS FOR BOTH STRUCTURES. ELECTRICAL VIOLATION 16-11C 2&3 HAVE BEEN PARCIALLY ABATED. OWNER HAS REMOVED EXTENSION CORD AND HAZARDOUS ELECTRICAL FROM SHED. ALL ULTILITIES ARE CURRENTLY ON. LAST CONVERSATION WITH OWNER STATED HE WOULD BE CONTACT TOM INGRAM AT CCD FOR HELP WITH DEMO PROJECT. ATTEMPTED CONTACT TOM INGRAM AT CCD FOR INFORMATION CONCERNING THIS PROPERTY. TOM NOT IN LEFT REQUEST FOR INFORMATION AND REQUESTED RETURN CALL AND OR EMAIL WITH UPDATE. WILL CONFER WITH INSP. 2 RICK SALDATE BEFORE ANY ACTION IS TAKEN. ALSO WILL AWAIT CONTACT FROM CCD.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00286
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
04/22/2005 CONTACTED BY PHONE
04/22/2005 NOTICE OF VIOLATION ISSUED
04/22/2005 COURT ORDERED ABATEMENT
02/15/2006 VIOLATION CLOSED