Case: T05DV00279
Case Details
Entered Date:
04/13/2005
Applicant:
FELIX ISMAEL & PATRICIA JT/RS
Description:
COMPLAINT: MIN HOUSING- NO UTITLITES
Outstanding Inspections
Case Number: T05DV00279
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 22
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected | ||
| NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
| VIOL(BL) - DETACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - ATTACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - FOUNDATION | None | Not Inspected | ||
| VIOL(BL) - LIVING AREAS | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| VIOL(EL) - CIRCUITS | None | Not Inspected | ||
| VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| VIOL(EL) - FIXTURES | None | Not Inspected | ||
| NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
| NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
| VIOL(PL) - FIXTURES | None | Not Inspected | ||
| NPO(PL)-WATER HEATERS | None | Not Inspected | ||
| NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
| NPO(DL)-DILAPIDATED STRUCTURE | None | Not Inspected | ||
| VIOL(SA) - BATHS | None | Not Inspected | ||
| VIOL(SA) - KITCHEN | None | Not Inspected | ||
| NPO - INSECTS/PESTS | None | Not Inspected | ||
| NPO - EGRESS | None | Not Inspected | ||
| NPO - SMOKE ALARMS | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00279
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2005 | INSP - INITIAL CODE ENFORCMENT | MROMERO | Approved | INTERIOR: LIVING ROOM: FRONT DOOR DOES NOT CLOSE PROPERLY (STUCK). 2 WINDOWS BOTH PAINTED & NAILED SHUT. FURNACE VENT COVERED, LACKING FURNACE. SOUTHWEST B.R.: 2 WINDOWS PAINTED OR NAILED SHUT, NORTH WALL WARPED. CLOSET APPEARS TO HAVE BEEN ADDED, 24" OPENING. KITCHEN: STOVE, NO VENT ABOVE FOR VENTING FUMES, GAS LINES FOR STOVE NOT PROPERLY BRACED & KINKED IN FLEX LINE. FLEX LINE HAS 2 KINKS. SINK LEAKS UNDER CABINETS, ALLOW FOR SEEPAGE OF GRAY WATER ON FLOORING. FLOORING VINYLE COMING UP DUE TO SEEPAGE. DISHWASHER NOT WORKING. GAS LINE STUBED OUT WHERE ORIGINAL STOVE & VENT WERE LOCATED. DINNING AREA: LOOSE ELECTRIC BOX & NEW PLUMBING LINES FOR SHOWER NOT SECURED. EXPOSED & NOT SUPPORTED. TC. SEC. 16-4 PERMITS REQUIRED: NEW MAIN DISCONNECT INSTALLED; NEW PVC WATER MAIN INSTALLED. REAR PORCH/SPAN 5'16" ON CENTER MOUNTED TO FASCIA LACKING APPROPRIATE HARDWARE. GAS LINE: UNDER PORCH IS NOT PROPERLY SECURED TO WALL. HOW WATER HEATER, FLEX LINE TWISTED: CHINKED IMPROPERLY INSTALLED, GRASS GROWING THROUGH IT. TC. SEC. 16-11(A) FIRE SAFETY: S.D. REQUIRED @ S.W. BEDROOM; NO S.D. @ SOUTH BEDROOM. S. BEDROOM CLOSET, REMOVE PULL CHAIN. TC. SEC. 16-11 (C) ELECTRICAL SYSTEMS: NEW MAIN DISCONNECT INSTALLED, N. SIDE: SEPERATED CONDUIT, IMPROPERLY SUPPORTED CONDUIT, ROMEX NOT PROTECTED, NON W.P. BOX ADJACENT TO COOLER: A/C UNIT AT S. BEDROOM REQUIRES DED. CIRCUIT: LIGHT FOR BATHROOM LOOSE. TC. SEC. 16-11 (E) PLUMBING SYSTEMS: NEW PVC WATER MAIN RUNNING AT SURFACE FOR EXTENDED LENGHT; VENT PIPE AT EXTERIOR FOR KIT. SINK BUSTED AND SEPARATED, NO SUPPORT FOR VERTICAL 1 1/2 VENT: EXTERIOR DRAIN PIPE SUBJACENT TO KIT. SINK BROKEN FOR ACCESS, NO CLEAN-OUT. NEW PLUMBING LINES INSTALLED GOING INTO KIT. AREA @ N. SIDE, APPEARS SHALLOW AND UNPROTECTED; EXPOSED VENT SYSTEM FOR WASHER AREA - NOT SUPPORTED, IMPROPERLY INSTALLED; WASHER DISCHARGE TUBE NOT PROPER MATERIALS; HOSE PENETRATING INTO WALL - INTO INTERIOR WASHER. TC. SEC. 16-11 (F) INTERIOR SURFACES & FEATURES: LACKS DOOR KNOB BETWEEN BEDROOMS: WINDOWS NOT OPENABLE AT S. BEDROOM. TC. SEC. 16-11 (I) CEILING HEIGHTS: IMPROPER @ S. BEDROOM 6'8". TC. SEC. 16-11 (J) ACCESS CONTROL: SINGLE CYLINDER KEY-LOCK AT S.W. BEDROOM DOOR. TC. SEC. 16-12 (A) EXTERIOR SURFACE/WEATHER PROTECTION DILAPIDATED STRUCTURES: WINDOW MISSING @ N.SIDE LIVING RM, FOUNDATION REQUIRES METALIC FABRIC MATERIAL AT ALL VENTALATION OPENINGS TO AVOID RODENTS, FOUNDATION REQUIRES CAUCK SEALANT AT ALL BOTTOM PLATE AND VERTICAL SEAMS OF SHIPLAP WALl. TC. SEC. 16-12 (D) COOLERS: COOLER NOT OPERATING, LACKS PROPER CONNECTIONS. TC. SEC. 16-12 (E) ACCESSORY STRUCTURES: COOLER STAND NOT IN A SOUND CONDITION, FALLING. MISC: RODENT CONTROL, EXTERIOR - OPENINGS TO SUB FLOOR NOT SCREENED OF @ EXTERIOR. |
| 09/20/2005 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | MRS. FELIX HAS PULLED PERMIT FROM D.S.D #T05CM01893. REF. ELEC. PANEL AND PLUMBING. UNIT IS CURRENTLY OCCUPIED. E.S HAS OPEN CASE FOR DEBRIS. CLOSE |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00279
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 04/21/2005 | CONTACTED BY PHONE |
| 04/21/2005 | NOTICE OF VIOLATION ISSUED |
| 04/21/2005 | COURT ORDERED ABATEMENT |