Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

03/25/2005

Applicant:

MARTIN CLATIE JEAN

Description:

COMPLAINT RE: MIN HOUSING- REFERRAL FROM TUCSON WATER. METER HAS BEEN PULLED, DUE TO TAMPERING. BALANCE OWED.

Outstanding Inspections

Case Number: T05DV00238
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 21
End Date Description Inspector Results Comments
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - DETACHED STRUCTURES None Not Inspected
VIOL(BL) - FOUNDATION None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(PL)-GAS SUPPLY/CONNECT None Not Inspected
NPO(PL)-SEWAGE DISPOSAL (SYS) None Not Inspected
VIOL(PL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
NPO(HC)-COOLING None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
NPO(DL)-DILAPIDATED STRUCTURE None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - EGRESS None Not Inspected
NPO - SMOKE ALARMS None Not Inspected
03/31/2005 INSP - INITIAL CODE ENFORCMENT MROMERO Violation On site inspection showed multiple peoplpe outside of dwelling, I spoke to tenants to advice them of my inspection and why I am conducting a inspection. Inspection is being conducted due to no water meter removed by Tucson Water, and tenants stealing water from neighbors. Exterior; open trench in backyardfor gas pressure test which the permit had expired.Gas line capped. trash and debris through out the entire property, tenant stealing water from norh side lot. Hot water heater has been removed water supply lines capped. No gas, water, or hot water heater. Swamp cooler mounted in back window with plywood and metal bracing. Water line looks to be added illegally on back wall, no bracing or supports. Added curcuit for backyard Ramada light and fan with extenion cord spliced as perment wiring. 100 amp service panel looks to be aproved no violations found. Drain pipes for kitchen and bath sinks is detearerated and added in exterior of of back house with out permits, 2 1/2 inch galvinized pipe coming out of wall a a 45degree angle to drin into a 4 inch Y vent pipe which is not approved. connection not the same size do not allow for a proper seal.

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00238
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/30/2005 INSP - FOLLOW UP CODE ENFORCE MROMERO Approved INSPECTION RESULTS SHOWS OWNER HAS PULLED PERMITS FOR WORK TO PLUMBING SYSTEM. AND HAS PERMITS FINALED. TENANT ARE OUT AND HAVE NOT BEEN BACK. ALL VIOLATIONS HAVE BEEN ABATED. CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00238
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
03/31/2005 CONTACTED BY PHONE
03/31/2005 NOTICE OF VIOLATION ISSUED
03/31/2005 COURT ORDERED ABATEMENT
10/06/2005 VIOLATION CLOSED

Documents

File Name Document Type  
FRONTPAN.JPG None VIEW
GAS DISCONNECT.JPG None VIEW
HAZ WIRING IN RAMADA.JPG None VIEW
INCORRECT PLUMBING DRAINING INTO VENT.JPG None VIEW
MISSING HOT WATER HEATER.JPG None VIEW
NOT ABLE TO FLUSH TOILET.JPG None VIEW
POSTING UNFIT .JPG None VIEW
RAMADA LIGHT SWITCH.JPG None VIEW
SERVICE PANEL OK.JPG None VIEW
SMOKE DETECTOR NOT WORKING.JPG None VIEW
SPACE HEATER.JPG None VIEW
TRENCH FOR GAS LINE.JPG None VIEW
VENT DRAIN NOT APPROVED.JPG None VIEW
VENT DRAIN.JPG None VIEW
VENT DRAINFROM KITCHEN AND BATHSINK.JPG None VIEW
WASHING MACHINCE DRAIN.JPG None VIEW
WATER HOSE FROM NEIGHBORS ILLEGAL.JPG None VIEW
WATER METER REMOVED.JPG None VIEW
WATER SUPPLY.JPG None VIEW
WATERHOSE FROM NEIGHBORS.JPG None VIEW