Case: T05DV00160
Case Details
Entered Date:
02/25/2005
Applicant:
TAMAYO AMADO & ADRIANA JT/RS
Description:
COMPLAINT:MIN HOUSING-
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00160
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2005 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE, MET WITH OWNERS WIFE AND TENANTS (ABEL) WALKED INTERIOR & EXTERIOR OF UNIT. MIN HOUSING ISSUES FOUND WERE AS FOLLOWS: ELECTRICAL 1) 3 PRONG RECEPTACLE TESTED IN WEST BEDROOM FOUND RECURSED HOT NEUTRAL. 2) NO GFI PROTECTION IN KITCHEN & BATHROOM 3) LIGHT SWITCH BY DOOR NOT COOLING OPENING & IS DOBLE GANG BOX WITH SWITCH MISSING. 4) EXTERIOR LIGHT FIXTURE HAS EXTINTION CORD PLUGGED INTO APPLIANCE CORD THEN TO LEGALLY SPLICE APPLIANCE CORD. 5) ELECTRICAL DISCONNECT MISSING DEAD FRONT COVER-ABATED 4/6/05 IILLEGALLY USE OF EXTENTION CORD CONNECTED & DOUBLE BUGGED TO BREAKER (15 AMP) NUCTURAL WIRCS 3 ARE BARUT & MAX HAVE SHORTED OUT. N.O.V WAS ISSUED FOR HAZARDOUS ELECTRICAL TO OWNER-ABATED 4-6-05. 6) ILLEGALLY INSTALLED RECEPTACLE & SWITCH WITH EXPOSED ELECTRICAL CONDUCTOR IN LAUNDRY ROOM. ILLEGALLY SPLICED ABATED 4-6-05 WEATHER STRIPPING & PROTECTION 1) FRONT & BACK DOOR LACKING WEATHER STRIPPING & TRESHOLDS. 2) ALL WOOD SURFACES LOCK PAINT PROTECTION COVER PERMITS REQUIRED WORK WITHOUT PERMITS ADDITION OF 6 X 12 APPROX ROOM HAS BEEN ADDED TO EAS SIDE OF STRUCTURE STUCCO REMAINS UNFINISHED LACKS PAINT PROTECTION COOLER STAND. NOT STRUCTURALY SOUND & LACKING PAINT PROTECTIONS PLUMBING 1) TEMPORARY REPAIRS HAVE BEEN DONE TO RENT PIPES 2)VENTS DO NOT TERMINATE ABOVE ROOF LINE 2 FEET 3) ADDITION OF WATER LINE USEE OF UNAPPROVED MATERIALS & NOT SECURED TO WALL EXTERIOR SURFACES 1) SEVERAL HOLES IN WALL FOR PLUMBLING PENETRATION W/O/P 1) ADDITION OF 6 X 8 LAUNDRY ROOM ATTACHED TO MAIN STRUCTURE 2 X 4 SPANING OVER 4" LOCKING CONNECTING HARDWARE, WOOD HAS CAN STRUCTURED OVER, REQUIRES PER MT. PICTURES WERE TAKEN. |
| 12/26/2007 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | VISITED SITE FOR COMPLIANCE INSPECTION,NO ACTION HAD BEEN TAKEN ON CASE DUE TO MISPLACED FILES. SITE INSPECTION FOUND THE FOLLOWING: 1-PERMIT REQUIRED 1-LAUNDRYROOM INSTALLED WITHOUT PERMITS. VIOLATION ABATED. LAUNDRYROOM HAS BEEN REMOVED. 2- VIOLATION ABATED: STUDS SPANNING MORE THAN 4 FT HAVE BEEN REMOVED. 3- ROOM EXTENDED: VIOLATION CAN NOT BE VERIFIED. WORK TOO OLD TO BE DETERMINED W/O/P. VIOLATION DISMISSED. 2- PERMITS REQUIRED ELECT SYS: VIOLATION ABATED UNDER PERMIT #T05EL00553 3- MECH. EQUIPMENT: AIR DEFUSER INSTALLED VIOLATION ABATED. 4- UNABLE TO VERIFY: REMOVE AS VIOLATION. 5- INTERIOR FIXTURES: NEW DOOR HAS BEEN INSTALLED,VIOLATION ABATED. 6- WEATHER PROTECTION: VIOLATION ABATED,NEW THRESHOLD, & WEATHER STRIPPINGS. 7- COOLERS VIOLATION ABATED,WINDOW UNIT REMOVED & ROOF TOP UNIT HAS BEEN INSTALLED. OWNER HAS ABATED ALL VIOLATIONS. MARK CASE COMPLIANT. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00160
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 04/04/2005 | NOTICE OF VIOLATION ISSUED |
| 04/04/2005 | COURT ORDERED ABATEMENT |
| 01/15/2008 | VIOLATION CLOSED |