Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING

Entered Date:

02/02/2005

Applicant:

ROMERO JESUS M & ARAIZA MARY CARMEN

Description:

COMPLAINT RE: MIN HOUSING -

Outstanding Inspections

Case Number: T05DV00080
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
02/14/2005 INSP - INITIAL CODE ENFORCMENT GGOODMAN Violation 2/02/05 VISITED SITE, AN EMERGENCY CALL OUT FROM INSPECTOR 2 (RICK SALDATE), UPON ARRIVAL, TALKED WITH OFFICER BRADWAY, AND OFFICER DISON. OFFICER DISON SHOWED US TO THE ELECTRICAL PANEL, THE METER WAS NOT INSTALLED, AND 150 FT. OF EXTENSION CORD WAS BEING RUN FROM THE DWELLING FROM THE SOUTH, OWNER OF THE DWELLING TO THE SOUTH ( SON OF THE OWNER TO 1325 W DELWARE) ,AND OWNER OF WEST DELWARE HAS DAUGHTER STAYING IN THE HOUSE WHERE POWER IS BEING SUPPLIED. STRUCTURE HAD A FIRE IN NOV. OF 04, SOUTH EAST CORNER OF HOUSE, AND HAS LACKED ELECTRICAL SERVICE SINCE THAT TIME. INTERIOR: KITCHEN HAS SMALL AMOUNT OF TRASH AND DEBRIS. LIVINGROOM HAD CLOTHES, STEREOS, TV'S,TOOLS, TRASH AND DEBRIS. BEDROOM 1, NORTHWEST BEDROOM, HAS BROKEN FURNITURE, OUTLETS AND SWITCHES LOOK GOOD, LITE FIXTURE HAS BEEN TAMPERED WITH, USING 2 LITE SOCKETS IN 1. BATH LACKS GFCI PROTECTIONS AT OUTLETS.BATH SINK CONTINUOSLY LEAKS. BEDROOM 2, SOUTHEAST BEDROOM, CEILING MISSING 4' BY 15' OF DRYWALL; MASTER BATH TOILET IS USABLE, HOWEVER THE SHOWER HAS A DRESSER WITH CLOTHES INSIDE IT.SOUTHWEST BEDROOM IS CLUTTERED WITH CLOTHES, THE BED IS INSIDE THE CLOSET. A PERMIT WILL BE REQUIRED FOR REPAIRS TO THE BURNT SECTION. ROMEX IN CEILING IS IN USABLE CONDITION. REAR YARD HAS STORAGE SHED, AND TRAVEL TRAILER, TRAVEL TRAILER IS SECURED AT THIS TIME. BEDROOMS HAD WROUGHT IRON SECURITY BARS ON WINDOWS, WITH DOUBLE KEYED DEADBOLTS ON HINGED OPENINGS, BROUGHT UP ISSUES WITH HOMEOWNER, HE SAID HE WOULD REMOVE THEM. OWNER OF PROPERTY WAS ON SITE, I EXPLAINED THE ISSUES OF HAVING TO SHUT DOWN THE STRUCTURE. ASKED IF OWNER'S DAUGHTER, WHO LIVES IN THE STRUCTURE WOULD HAVE A PLACE TO STAY, HE SAID HE WOULD GET HER A PLACETO STAY. OWNER ASKED WHAT IT WOULD TAKE TO REOCCUPY THE STRUCTURE, I EXPLAINED FIRST AND FOREMOST TO RESTORE ELECTRICAL SERVICE. I WILL LET HIM KNOW IF ANY MORE ISSUES AFTER INSPECTION. DID GO OVER ALL ISSUES WITH OWNER. SHUT DOWN UNIT FOR LACK OF ELECTRICAL POWER, POSTED UNIT AND TOOK PICTURES.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00080
Case Status: VOID
Total Completed Case Activity Conditions: 2
Date Name
02/14/2005 VIOLATION CLOSED
02/14/2005