Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T05DV00052
Case Details
Entered Date:
01/25/2005
Applicant:
BARAJAS JAVIER & ROSEMARY P JT/RS
Description:
COMPLAINT:MIN HOUSING- MIN HOUSING ISSUES REFERRED BY DSD
Outstanding Inspections
Case Number: T05DV00052
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 13
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected | ||
NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
VIOL(BL) - ATTACHED STRUCTURES | None | Not Inspected | ||
VIOL(BL) - LIVING AREAS | None | Not Inspected | ||
VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
NPO(PL)-WATER HEATERS | None | Not Inspected | ||
NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
VIOL(FS) - EMERGENCY ACCESS | None | Not Inspected | ||
02/18/2005 | INSP - INITIAL CODE ENFORCMENT | JHURD | Correction Required | 2/14/05, VISITED SITE, TOOK PICTURES, MET WITH RESIDENTS DAUGHTER HILDA,ON SITE, HILDA DID NOT KNOW MUCH ABOUT THE CALL OR DWELLING, DID ASK IF WE COULD LOOK AROUND, STATED YES I GUESS, DID LOOK AROUND, FOUND THAT HEATER HAS BEEN TAGGED BY SOUTHWEST GAS BACK IN 2/28/04, UNIT HAS BEEN LACKING GAS SINCE. SECURITY BARS ON ALL WINDOWS NOT OF BREAK AWAY TYPE, FRONT SECURITY DOOR HAS 2 HANDLES, RESIDENT HAD TO OPEN DOOR WITH A KNIFE DUE TO BROKEN HANDLES, BACK DOOR LACKING DEADBOLT, BOTH DOORS LACK PROPER WEATHER STRIP.BEDROOM LIGHT FIXTURE REPLACED TO CERAMIC TYPE, HOLES IN DRYWALL, ADDITION ADDED TO EAST SIDE BEING USED AS BEDROOM, ( ADDITION WITHOUT PERMITS ). HOT WATER HEATER NEWER INSTALLATION, LACKS SHUT OFF VALVES AND VENTING NEEDS TO BE RECONNECTED,(WATERHEATER WITHOUT PERMITS ). WASHER WATER SUPPLY LINES ADDED, EXTERIOR EAVES IN NEED OF RESEALING,EXTERIOR SIDING HAS HOLES, PATCHES IN SIDING INSTALLED IMPROPERLY (ALLOWS LEAKING). SIDING UNFINISHED, CORNERS MISSING. PORCH LACKS RAFTERS TO SUPPORT METAL ROOF AND PORCH LACKS PROPER CONNECTORS IE. POST TO BEAM ,POST TO CONCRETE ETC... PIGIONS ARE IN SIDE OF WALLS, COULD HEAR THE COOING. WASHER, DRYER ROOM POSSIBLY WORK WITHOUT PERMITS. NEW ELECTRIC, PROPABLY WORK WITHOUT PERMITS, HAS IMPROPER GROUNDING.EXPOSED ROMEX IN ADDITION. CONTACTS: OWNER, JAVIER BARAJAS 230-3109 PO BOX 42251 TUCSON,AZ 85733 REFERAL: D.S.D.C. INSPECTOR HENDRICKS |
07/05/2005 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Correction Required | 7/1/05, VISITED SITE, TOOK PICTURES, FOUND HEATER STILL TAGED BY SOUTHWEST GAS, SECURITY BARS ON BEDROOM WINDOWS HAS BEEN REMOVED, FRONT DOOR SECURITY DOOR HAS BEEN REPAIRED AND OPERATES AS INTENDED, EXTWERIOR WALLS HAS BEEN SEALED AND ALL WOOD PAINTED, MOST OF NOTICE AND ORDER DONE, EXCEPTION IS LACKS PERMIT FOR ELECTRICAL UPGRADE, PERMIT FOR ROOM ADDITION, PERMANATE HEATER TAGED BY SOUTHWEST GAS. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00052
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
01/25/2005 | CONTACTED BY PHONE |
03/04/2005 | NOTICE OF VIOLATION ISSUED |
03/04/2005 | COURT ORDERED ABATEMENT |
10/27/2006 | VIOLATION CLOSED |
01/31/2006 | CITATION #6434328 ISSUED BY MAILING |