Case: T05DV00042
Case Details
Entered Date:
01/19/2005
Applicant:
SOUTH EDWARD & ONELIA TR
Description:
COMPLAINT RE: MIN HOUSING- PLUMBING SYSTEM VERY OLD, CAN'T USE SINK IN KITCHEN DUE TO IT BACKING UP. ONGOING ISSUES W/ PLUMBING SYSTEM. FLOOR IN BATHROOM IS COMING APART (VINYL). KITCHEN & HALLWAY CEILING HAS CRACKS & WATER DAMAGE.
Outstanding Inspections
Case Number: T05DV00042
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00042
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/04/2005 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | #2 VISITED SITE MET WITH OWNER & LOUISA FROM REALTY CO. MECHANICAL: 1) WALL FURNACE REQUIRES SERVICING, FURNACE INSTALLED IN KITCHEN AREA. ELECTRICAL: 1) OPEN GR. REC. IN KITCHEN SINK AREA. 2) NO GFIC PROTECTION IN KITCHEN. 3) HAZARDOUS ELECTRICAL, CONDUCTOR NOT IN CONDUIT IN BATHROOM. 4) BATHROOM LIHGT FIXTURE HAS NONE GROUNDED REC. 5) J-BOX LACKS COVER PLATE IN LIVING ROOM & BATHROOM. 6) ELECTRIC STOVE - ELEMENTS MISSING. 7) EXPOSED ELECTRICAL J-BOXES IN BEDROOM CEILING & ADDED CIRCUITS. FIRE SAFETY: 1) NO WORKING SMOKE DETECTORS. 2) BATHROOM WINDOW CRANK NOT WORKING. PLUMBING: 1) SHOWER INSTALL NOT MADE OF NON-ABSORBENT MATERIALS. 2) GAS PIPING - W/O/P - NOT ANCHORED, RUNS TO WALL FURNACE AND INTO BEDROOM CLOSET. 3) HOT WATER HEATER TANK LACKING TRP DRAIN VALVE, COLD WATER SHUT OFF, VENT PIPE NOT SECURED. 4) ADDITION OF COPPER WATER SUPPLY LINES. WEATHER PROTECTION: 1) FRONT DOOR LACKING WEATHER STRIPPING. 2) WOOD FASCIA LACKING PAINT PROTECTION. ZONING: 2 - SHEDS NOT SET BACK AS REQUIRED. UNIT #3 ELECTRICAL: 1) OPEN GR. AT KITCHEN RECP. - & LACKING GFCI PROTECTION. 2) REC. IN BATHROOM NOT SECURED TO WALL. 3) W/O/P ADDED ELECTRICAL CIRCUITS, CONDUCTORS NOT IN CONDUIT. 4) NO GFIC PROTECTION IN BATHROOM. 5) RECEPTACLES TESTED SHOW NO GR. IN BEDROOM & NOT SECURED TO WALL. INTERIOR FEATURES: 1) BEDROOM DOOR HAS BROKEN STYLES & DOOR SKIN COMPLETELY GONE. MECHANICAL: 1) LACKING EXHAUST VENT IN KITCHEN FOR STOVE. PLUMBING: 1) TOILET BOWEL NOT SECURED TO FLOOR. HEATING: 1) UNITS HEATING NOT WORKING, BLOWER MOTOR HAS BEEN REMOVED, TENANT IS USING SPACE HEATER IN A HAZARDOUS MANNER & WERE PROVIDED BY OWNER. UNIT #1 ELECTRICAL: 1) EXPOSED ELECTRICAL FLORESENT LIGHT FIXTURES NOT HARD WIRED. 2) NO GFIC PROTECTION FOR RECEP. IN BATHROOM. 3) POSSIBLE LAUNDRY ROOM, FLORECENT LIGHT FIXTURES INSTALLED WITH NON APPROVED ELECTRICAL CONDUCTORS, EXTENTION CORD RUNS TO SWITCH THEN TO OUTLET. 4) EXTENTION CORD BEING USED AS ELECTRICAL CIRCUIT, RECEPTACLE FOR STOVE IS 2-PRONG & LACKS PROPER GR. ADAPTORS. 5) RECEPTACLES WERE TESTED & FOUND TO BE LACKING EQUIPMENT GRS. ALL WILL REQUIRE ASSESSMENT BY ELECTRICAL CONTRACTOR. 6) NEW TYPE CIRCUIT BREAKER BOX, POSSIBLE UP-GRADE, 1-NEUTRAL IN GRD. BAR. PLUMBING: 1) W/O/P - 3/8 COPPER LINES RUN FROM HALL WALL TO CEILING ALONG KITCHEN CEILING & DROP DOWN INTO KITCHEN SINK AREA, NOT AN APPROVED METHOD OF INSTALLATION. 2) KITCHEN SINK PLUMBING LEAKING. 3) NEW ABS INSTALLED IN KITCHEN. 4) 3/8 WATER LINES RUNS APPROX. - 10 FEET ALONG OUTSIDE WALL NOT APPR. MECHANICAL: 1) HOT AIR FURNACE REQUIRES SERVICE & TEST FOR CO. BY HEATING CONTRACTOR. 2) COOLER STAND, WOODEN SECTIONS IN A DETERIORATED STATE. WEATHER PROTECTION: 1) FRONT DOOR LACKS WEATHER STRIPPING. FIRE SAFETY: 1) WINDOWS PAINTED SHUT IN SW BEDROOM. 2) WINDOW LACKS LOCKING MECHANISM. W/O/P: 1) ADDITION OF PORCH TURNED INTO LIVING SPACE. STRUCTURAL: 1) REQUIRED VENT FOR PITCHED ROOF HAS BEEN BLOCKED OFF. PICTURES WERE TAKEN. |
| 05/16/2007 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | ATTENDED COURT, PRESENT WERE DNR INSPECTOR H.LOPEZ, CITY PROSECUTOR PAT MERKOFF AND PROPERTY OWNER. OWNER HAS ABATED ISSUES. ABATEMENT PERIOD EXTENDED. NO ADDITIONAL FINES WERE IMPOSED. $750.00 DEFAULT WAS SUSPENDED. ORIGINAL FINE HAS BEEB PAYED. CASE CLOSED. MARKED CASE ABATED.PN |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00042
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
| Date | Name |
| 01/24/2005 | CONTACTED BY PHONE |
| 04/21/2006 | CONTACTED IN PERSON |
| 03/31/2006 | CONTACTED BY MAILING |
| 12/08/2005 | NOTICE OF VIOLATION ISSUED |
| 12/06/2006 | POSTING/PUBLICATION |
| 04/08/2005 | COURT ORDERED ABATEMENT |
| 06/22/2007 | VIOLATION CLOSED |
| 03/28/2007 | COURT HEARING INFO |