SCHONFELD CHARLES W 1996 INTER VIVOS TR 1/2 &

Description:

Full Inspection

Outstanding Inspections

Case Number: T04FR00732
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
12/06/2004 VIOL - BUILDING SVCS & SYSTEMS TKNAPP Correction Required 605.3 Working space and clearance - The electrical control panels at the north side of the store shall have a clear working space 36 inches in depth and the width of the equipment.
12/06/2004 VIOL - FIRE RESIST.RATED CONST TKNAPP Correction Required 703.1 Maintenance - The fire resistance rating of the ceiling shall be maintained. The ceiling tiles in the stockroom and in the janitors closet shall be replaced.
12/06/2004 VIOL - MEANS OF EGRESS TKNAPP Correction Required 1026.3 Exit sign illumination - The exit sign at the north center exit corridor shall be repaired.
12/06/2004 VIOL - MEANS OF EGRESS TKNAPP Correction Required 1026.5 Illumination emergency power - The emergency lighting at the north center exit corridor shall be repaired.
12/06/2004 VIOL - MEANS OF EGRESS TKNAPP Correction Required 1027.3 Obstructions - A means of egress shall be free from obstructions. The exit corridor at the north center of the store shall not be obstructed.
12/06/2004 VIOL - MEANS OF EGRESS TKNAPP Correction Required 1027.6 Panic hardware - Where panic hardware is installed, the panic hardware shall be the only locking device on the door. Locking bars shall be removed from north side doors.

Completed Inspections

Case Status: COMPLETE
Case Number: T04FR00732
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/23/2004 INSP - FULL TKNAPP Approved