Case: T04DV00996
Case Details
Entered Date:
12/28/2004
Applicant:
FEDIGAN MARTIN J TR
Description:
COMPLAINT RE: MIN HOUSING- BREAKER BOX EXPOSED, 2 OUTLETS IN KITCHEN, POWER GOES OUT WHEN USING MORE THAN 1 OUTLET. PIPES FOR PLUMBING ROTTED & CLOGGED UP. PIPES HAVE HOLES AND LEAKING (MOLD GROWTH). TOILET BACKING UP, LEAKING WATER FROM TOP TANK & BOTTOM OF TOILET BREAKING (CAN'T USE). BATHTUB FILTHY ALSO BACKING UP. CABINETS IN KITCHEN & BEDROOM DETERIORATED, FALLING OFF. ALL WINDOWS CRACKED/BROKEN, DON'T SECURE PROPERLY. WALL HEATER GETS VERY HOT, DAMAGING WALL. UNIT INFESTED W/ RATS AND ROACHES.
Outstanding Inspections
Case Number: T04DV00996
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T04DV00996
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2005 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE, MET WITH TENANTS WALKED PROPERTY MIN HOUSING VIOLATIONS ARE AS FOLLOWS. TENANT HAVE OCCUPIED UNIT FOR APPROXIMATELY 5 MONTHS, VERBAL ARRANGEMENT WERE MADE FOR REPAIRS TO STRUCTURE BETWEEN TENANT AND OWNER. ELECTRICAL 1. EXPOSED AND UNPROTECTED ELECTRICAL CONDUCTORS FOR WASHING MACHINE AND DRYER LEADING FROM ELECTRICAL PANEL. 2. EXPOSED ELECTRICAL NOT IN CONDUIT IN FRONT AREA ABOVE LIVINGROOM WINDOW. 3. ADDITION OF J-BOX WITH RECEPTACLES HAVE BEEN INSTALLED IN A HAZARDOUS MANNER, ELECTRICAL CONDUCTOR SHEETING HAS EXPOSED ELECTRICAL WIRE 1-SWITCH 1-220 RECEPTICAL AND 1 J-BOX W/RECEPTICLE IN CEILING. 4. EXTENSION CORD HAS BEEN TAPPED TO WALL APPROXIMATELY 14' TO PROVIDE POWER TO STOVE, STOVE HAS ELECTRICAL IGNITERS AND ELECTRIC POWER FOR GLOW PLUG TO OVEN. 5. SEVERAL SPRONG RECEPTICLES WERE FOUND LACKING MECHANICAL GROUND. STRUCTURAL ELETRICAL SYSTEM APPEARS TO BE (2) WIRE SYSTEM. 6. INTERIOR SUB-PANEL MAYBE LACKING DOOR. TENANT STATED BREAKER OCCASSIONAL TRIPS. ACCESSORY STRUCTURE 1. PORCH STRUCTURE HAS BEEN INSTALLED IN A HAZARDOUS MANNER, 2 X 4 HAVE BEEN USED TO SPAN OVER 4', LACKING PROPER ATTACHMENT HARDWARE, 2' X 6" BY 6" BEAM HAS BEEN INSTALLED INCORRECTLY. STRUCTURAL 1. EXTERIOR WALL CRACKED AT NORTH END OF STRUCTURE CRACKS EXTEND APPROXIMATELY 3 FEET AND ONTO FOUNDATION. PLUMBING 1. TPR DRAIN PIPE MISSING 2. WASHING MACHINE DRAINING INTO VENT PIPE AND LACK P-TRAP. 3. NEW GAS LINE APPEARS TO HAVE BEEN INSTALLED AND IS LACKING ANCHORS FOR WALL IN LAUNDRY ROOM AND FOR PIPING TO STOVE. 4. BATH TUB PLUMBING LEAKING BEHIND TUB ACCESSIBLE FROM ACCESS DOOR IN KTICHEN CABINETS. 5. KITCHEN SINK LEAKING AT STRAINER BASKET CONNECTION. 6. TOILET TANK WAS FOUND TO BE LEAKING. 7. TUB LACKING HOT WATER HANDLE AND WILL REQUIRE REPLACEMENT OF STEM. WEATHER PROOFING 1. SEVERAL WINDOWS FOUND CRACKED, OTHER TAPED OFF TO NOT ALLOW AIR TO ENTER UNIT. GASKETS COMING AWAY FROM FRAMES. BATHROOM WINDOW COVERED BY PLASTIC. 2. BOTH ENTRY DOORS LACKING WEATHER STRIPPING EVIDENCED BY LARGE AMOUNTS OF LIGHT SHINNING THROUGH WHEN DOOR IS CLOSED. FRONT ENTRY DOOR THRESHOLD WILL REQUIRE REPLACEMENT. MECHANICAL 1. DRYER VENT MISSING FOR DRYER 2. EXTERIOR DOOR FOR HOT WATER MISSING. 3. WALL FURNACE WILL REQUIRE SERVICE DUE TO LARGE AMOUNTS OF LINT IN UNIT. INTERIOR SURFACE 1. KITCHEN CABINETS LACK COUNTER POST STYLE ON 2-SIDE. 2. SEVERAL HINGES ARE SPRUNG. 3. UPPER CABINETS LACKING DOOR LATCHES. 4. SOUTHEAST BEDROOM CEILING SHOWS WOOD ROT, APPROXIMATELY 12" X 2" SECTION MAY HAVE BEEN CAUSED BY COOLER LEAK. PICTURES WERE TAKEN. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00996
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 01/03/2005 | CONTACTED BY PHONE |
| 02/04/2005 | NOTICE OF VIOLATION ISSUED |
| 02/04/2005 | COURT ORDERED ABATEMENT |
| 03/17/2006 | VIOLATION CLOSED |