Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

12/16/2004

Applicant:

MICHELLE DE LEON

Description:

COMPLAINT RE: MIN HOUSING-NO HEAT, HEATER NOT WORKING. CEILING IN BEDROOM & HALLWAY LEAKING WATER WHEN RAINS. TENANTS HAVE PATCHED SOME AREAS BUT STILL LEAKS. OWNER IS AWARE OF & STATES IT'S THEIR RESPONSIBILITY. OWNERS CONTACT # HAS CHANGED, DOSEN'T KNOW NEW #. OWNER ONLY CALLS WHEN THE RENT IS DUE.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00981
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/29/2004 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE, TOOK PICTURES, MET W/ RESIDENT WINNIE, RENTER ABOUT 5 YRS, STATED SHE CALLED DUE TO LANDLORD DOES NOT WANT TO MAKE REPAIRS TO HEATER - ROOF LEAK, WINNIE ALSO STATED OWNER TAKES OFF $50.00 A MONTH FOR RESIDENT TO DO UP KEEP ON HOUSE, RESIDENT HAS DONE A LOT, NEW TILE THROUGH, REMODELED HALL BATH, DID DO ENCLOSURE ON PORCH, STATED HAD CONTRACTOR DO WORK, THINKS PERMITS WERE PULLED? ELECT. SERVICE PANEL MISSING DEAD PLATE FRONT, 100 AMP SERVICE, 2 40 AMP BREAKERS ADDED FOR DRYER, EXPOSED WIRING 6 AWG, APPEARS KITCHEN ADDED ON TO, KITCHEN OUTLET WIRED CORRECTLY - NOT GFCI PROTECTED, FRONT DOOR BOTTOM LACKS PROPER WEATHER PROTECTION, HOLES IN DRYWALL AT WATER CONNECTION FOR WASHER, HOT WATER TANK FLUE PIPE LACKS SEALANT AROUND JOINTS, GAS VALVE NOT AGA APPROVED, HALL BATH FAUCET LEAKS, LIGHT FIXTURE MISSING COVER, HALL CEILING SHOWS EVIDENCE OF ROOF LEAK, RESIDENT STATES LEAKS WHEN RAINS, RESIDENT STATED HAD FRIEND LOOK AT HEATER, HE STATED HAD CRACKED SOMETHING. DID NOT TURN ON SUGGESTED TO HAVE S.W. GAS COME OUT AND START UP. M/B SECURITY BARS ON WINDOWS NOT BREAK AWAY. M/ BATH SHOWER CAULKING - GROUT MISSING IN AREA, TILES STARTING TO COME AWAY FROM WALL, MIDDLE B/R CONVENIENCE OUTLET MISSING COVER PLATE, SECURITY BARS ON WINDOW NOT BREAK AWAY, B/R S.W. COMPUTER ROOM, TO FULL, B/R S.E. ANIMAL-TERRARIUM W/ EXTENSION CORDS, B/R SHOWS LEAK IN CEILING, WENT UP ON LADDER, ENTIRE ROOF LACKS PROPER MAINTENANCE, ALL YARDS SHOW TRASH & DEBRIS, TRAVEL TRAILER ON WESTSIDE OF PROPERTY, OLD TRUCK IN REAR YARD, EXPLAINED TO RESIDENT I WILL BE CONTACTING S. WASTE TO COME OUT FOR YARDS, EXPLAINED TO RESIDENT THAT AT THIS POINT WOULD BE BEST TO CONTACT HEATING & COOLING CO. TO COME OUT AND EVALUATE HEATER AND DO C/O TEST THEN GET W/ OWNER ABOUT MONEY SPENT. OWNER IS TAKING OFF $50.00 A MONTH FOR RESIDENT TO DO UP KEEP ON PROPERTY.
05/13/2005 INSP - FOLLOW UP CODE ENFORCE JHURD Approved 5/12/05, SEE CONDITIONS.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00981
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/13/2005 CONTACTED BY PHONE
01/03/2005 NOTICE OF VIOLATION ISSUED
01/03/2005 COURT ORDERED ABATEMENT
07/28/2005 VIOLATION CLOSED