Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

11/23/2004

Applicant:

JIMMY JARIWALLA

Description:

COMPLAINT:MIN HOUSING-RE: LIVING CONDITIONS

Outstanding Inspections

Case Number: T04DV00923
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00923
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
11/29/2004 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE TOOK PICTURES, MET W/ OWNER JIMMY PROPERTY HOUSES, 22 UNITS TOTAL. (1ST BLD.) OFFICE & OWNERS UNIT 26-27: (UNIT 26) EXTERIOR, NORTHSIDE SUB PANEL ADDED CIRCUIT, EXPOSED ROMEX, SUGN BOXES MISSING KNOCK OUT PLUGS, ADDED ELECT. CIRCUIT, INSTALLED W/ P.V.C. PIPING, NOT SECURED TO WALL, WEATHER PROOF JUNCTION BOX NOT SECURED, BRICKS SHOWS SEPERATION (CRACKS), NORTHEAST CORNER EXPOSED WIRING TAPED, BACK EASTSIDE, WATER LINES (COPPER) HAS BEEN ADDED TO OFFICE, OWNERS UNIT 26. (UNIT 27) EXPOSED ON WALL, NO PROTECTION, TWO 50 GAL. HOT WATER TANKS CONNECTED TOGETHER BY WATER AND BY GAS 1/2'' LINE, WRONG VALVE, FLEX LINE CRIMPED AND BENT, NO EMERGENCY VALVE SHUT OFF, FLUE PIPE FALLEN OFF, DOES NOT EXTEND 3' ABOVE ROOF LINE, MAIN GAS LINE NOT BURRIED NOT SECURED TO WALL, GOES IN TO STRUCTURE AT TOP, HOLES & CRACKS IN BRICKS, PAINT PEELING, GAS LINE HAS BEEN REPLACED, GOING INTO UNITS APPROX 3' UP BACK WALL, DRYER VENT STICKING OUT OF WALL, SHARP EDGES, ELECT. LINE ADDED FOR HOUSE LAUNDRY ROOM, PANEL BOX AT TOP MISSING, KNOCK OUT PLUGS FACIAL BOARD DETERIORATING, PAINT PEELING, WATER LINE SHUT OFF VALVE MISSING HANDLE, HOT WATER TANK MISSING PRV DRAIN LINE. (INSIDE OFFICE LOBBY) SOME OUTLETS CHANGED, EXPOSED WIRING TO FLORESENT LIGHT, A/C UNITS INSTALLED NOT SEALED PROPERLY UNITS 26-27. (2ND BLD.) EASTSIDE UNIT 25: (UNIT 25) A/C UNIT INSTALLED, OUTLET NOT GFCI PROTECTED, OR WATER PROTECTED, HAS OPENINGS, NOT SEALED PROPERLY, EAVES DETERIORATED & ROTTED AWAY, EXTERIOR DOOR JAMB NOT SEALED PROPERLY. (UNIT 24) FRONT DOOR JAMB NOT SEALED PROPERLY, EASTSIDE OF UNIT 24 CARPORT WOOD DETERIORATED, ROTTED, EAVES DETERIORATED, ALL ELECT. BOXES AND JUNCTION BOXES CAN NOT REACH 6' TO 7' HIGH. (UNIT 25) EASTSIDE, FACIAL BOARD DETERIORATED, HOT WATER TANK PRV DOES NOT GO DOWN. (UNIT 23) REAR HOT WATER TANK MISSING PRV, WRONG GAS VALVE, PVC 40 WATER LINE HAS BEEN INSTALLED INSTEAD OF ORIGINAL, 40 GAL HOT WATER TANK SUPPLIES BOTH UNIT 23 & STORAGE ROOM, BOTH COLD & HOT, WIRE STICKING OUT OF BOX CONNECTED TO DOUBLE POLE 20 AMP BREAKER, TRAVELS APPROX 85' TO JUNCTION BOX STRANDER COOPER, RED-BLUE-BLK-BR ALL CONNECTED TO NETURAL BAR, NO DOUBLE LUGGING, FUSE PANELS ONE 200 AMP FUSES ONE TO N HAS 150 AMP FUSES, NEXT BOX HAS 200 AMP AND 125 AMP FUSES (400 AMP SYSTM) PANEL BOX SOUTH END MISSING CAPS. (FRONT OF UNIT 23 & GUEST LAUNDRY) ELECT. LINE ADDED, OUTLET NOT GFCI OR WEATHER PROTECTED, LAUDRY ROOM FLUE PIPE NOT DOUBLE WALLED, NOT 1'' CLEARANCE THROUGH ROOF, OUTLETS NOT GFCI PROTECTED, WASHER LACKS TRAP. (STORAGE ROOM #1) WATER LINE ADDED, EXPOSED WIRING TO LIGHT FOR APPL. CORD TO PLUG, FLORESENT LIGHT EXPOSED WIRE CONNECTION ADDED TO ELECT. CIRCUITS, EAST WALL 12 SEPERATE ELECT. BOXES TOP ROW 2ND LEFT TO RIGHT DOUBLE LUGGED LOAD SIDE, EXPOSED WIRING FROM SILVER BOX, 3RD BOX LEFT TO RIGHT DISCONNECT BROKEN, ICE MAKER ON TOP LACKS FUSE PROTECTION, EXPOSED WIRING TO LIGHT FIXTURES SOUTH END. (UNIT 21-22 REAR) OPEN ELECT. BOX, JUNCTION BOX NOT WEATHER PROTECTED, BREAKER BOX USING BLUE WIRE FOR NETURAL, EAST END OUTLET NOT WEATHER PROTECTED OR GFCI, DETERIORATED ROTTED, HOT WATER TANK HOUSING ROTTED. (UNITS 19-20) SUB PANEL SOUTHSIDE, WIRES SPLICED TOGETHER, 3 WIRES TO TOP LEFT SIDE TIES IN TO OTHERS, (WHEN MOVED), WIRES CAME APART RIGHT SIDE SAME WAY, BOX NEEDS TO BE CLEANED UP-EVALUATED, SEVEN 55 GAL. DRUMS IN REAR OF UNITS 19-20 ARE FOR ASPHALT COATINGS, EAVES DETERIORATED, CONDUIT TO A/C (UNIT 19) CAME APART. CARPORT BETWEEN UNIT 19-20 AND 18 DETERIORATED, MOVES, SWAYS WHEN PUSHED ON, ELECT. LINE IN CONDUIT WERE CONNECTED TO THIS STRUCTURE, CAME APART, ELECT. LINES HANGING NO SUPPORT. (UNIT 18) SOUTHSIDE, OUTLET NOT GFCI, OR WEATHER PROTECTED, FRONT DOOR JAMB NOT WEATHER PROTECTED, HOT WATER TANK MISSING SHUT OFF HANDLE, P.R.V. WRONG SHUT OFF, OPEN BOX UNDER EAVE, ROMEX CUT, HANGING ELECT. SUB PANEL, MISSING DEAD PLATE, CONDUCTOR (BLK WIRE) SHOWS MELTING OF INSULATION, ALSO NETURAL WIRE, (R) SIDE ALSO 4 WIRES ON (L) SIDE SHOWS OVER HEATING, MAIN WIRE #8 RUNNING BEHIND BREAKERS, JUNCTION BOX OPEN, EXPOSED WIRING, WIRE GOES FROM BLD. TO BLD. WHERE SECURE WOOD DETERIORATED WILL NOT HOLD CONDUIT. (UNIT 17) OPEN BOX, EXPOSED ROMEX SOUTHSIDE, OUTLET NOT GFCI, NOT WEATHER PROTECTED, OUTLET NOT GFCI, NOT WEATHER PROTECTED, HOT WATER TANK MISSING SHUT OFF HANDLE, DO NOT SEE P.R.V. (UNIT 16) WOOD TO HOLD ELECT. DETERIORATED, ELECT. LINES SAGGING, HANGING CARPORT WOOD DETERIORATED. (UNIT 15) ELECT. LINES NOT PROPERLY SECURED, OPEN BOX W/ ROMEX EXPOSED, WIRE CUT, OUTLET NOT GFCI, NOT WEATHER PROTECTED. (UNIT 14) HOT WATER TANK MISSING SHUT OFF HANDLE, MISSING P.R.V. DRAIN LINE, FLUE NOT CONNECTED TO HOT WATER TANK, DOES NOT EXCEED 3' ABOVE ROOFLINE 30 GAL. CARPORT DETERIORATED, WOOD SHEETING ROTTED, OUTLET NOT GFCI OR WEATHER PROTECTED. (UNIT 11-12) HOT WATER TANK MISSING P.R.V. DRAIN LINE, GAS VALVE UPSIDE DOWN, NOT ACCESSABLE. (UNIT 28) 3 VEHICLES CURRENTLY NOT REGISTERED, (1) BROWN VOLVO=564-CYX 12/01, GREEN CHEVY=458-EWC 3/03, WHITE FORD VAN NO PLATE, CARPORT TO NORTHSIDE WOOD ROOF SHEETING DETERIORATED, HAS HOLES, USING 2X4 FOR RAFTERS, OVER SPANED, 12' SPLICED, FRONT MISSING PIECE OF FACIA BOARD 10', ALL OTHER FACIA DETERIORATED, ROTTED, TO BOTH (UNIT 28-29), ALSO SOUTHSIDE FACIA DETERIORATED, REAR SIDE FACIA DETERIORATED, FALLING, HOT WATER TANK MISSING P.R.V. DRAIN LINE, FLUE PIPE NOT MOUNTED CORRECTLY & LEANING, UNITS 28-29 BACK DOORS COVERED W/ PLYWOOD. (UNIT 30) NEW CONDUIT ON NORTHSIDE SUPPLYING POWER TO UNIT, NEW SUB PANEL ADDED TO REAR SERVES ALL 3 UNITS 30,31,32 ALLOW DOUBLE POLE 20 AMP BREAKER. (UNIT 32-32) 4X4 SUPPORT POST NOT PROPERLY SECURED AT BOTTOM, ONE AT UNIT 32 HAS BEEN CUT AND MOVED EXISTING TO WEST ON TOP OF DECORATOR CURB, ALL REAR DOORS HAS BEEN BOARDED UNIT 30,31,32. (REAR OF UNIT 32) FUSE BOX DOUBLE LUGGED, NOT WEATHER PROOF, DETERIORATED. (UNIT 29) INTERIOR, SPLICED EXTENSION CORD TO A/C WINDOW UNIT, COOLER WINDOW UNIT EXPOSED WIRING TO SWITCH, WINDOW CRANKS MISSING, BACK DOOR SEALED SHUT, BATH WALL DETERIORATING FROM WATER LEAK, BATH WINDOW CRANKS BROKEN, SHOWER HEAD DIRTY WILL NOT ALLOW FOR GOOD WATER FLOW FOR SHOWER, LIGHT FIXTURE MISSING, L/R BEDROOM CEILING FAN WIRING SPLICED OVER BED, HEATER SEEMS TO OPERATE PROPERLY, NO C/O TEST, HEATER DOOR BROKEN, DWELLING LACKS SMOKE DETECTOR. (UNIT 30) INTERIOR, LACKS SMOKE DETECTOR, L/R BEDROOM LIGHT MISSING COVER, HEATER APPEARS TO OPERATE, NO C/O TEST, HAS GAS STOVE, PILOTS NOT LIGHT, KITCHEN SINK NOT SEALED PROPERLY, ABSORBENT MATERIAL EXPOSED. (UNIT 31) LACKS SMOKE DETECTOR, LIGHT MISSING COVER, ALL LIGHTS MISSING COVERS.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00923
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
03/12/2007 CONTACTED BY PHONE

Documents

File Name Document Type  
741 E MIRACLE MILE 5 22 07 001.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 002.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 003.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 004.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 005.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 006.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 007.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 008.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 009.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 010.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 011.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 012.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 013.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 014.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 015.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 016.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 017.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 018.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 019.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 020.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 021.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 022.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 023.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 024.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 025.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 026.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 027.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 028.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 029.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 030.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 031.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 032.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 033.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 034.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 035.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 036.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 037.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 038.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 039.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 040.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 041.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 042.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 043.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 044.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 045.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 046.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 047.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 048.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 049.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 050.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 051.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 052.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 053.JPG IMAGES VIEW
741 E MIRACLE MILE 5 22 07 054.JPG IMAGES VIEW
NOTES 01-10-07.PDF DOCUMENTS VIEW