Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

11/23/2004

Applicant:

MORRISON ROBERT L & CATHY A

Description:

COMPLAINT:MIN HOUSING-FLOOR TILE COMING UP IN BATHROOM, HALLWAY, KITCHEN. CEILING IN LIVINGROOM COMING DOWN. MISSING KITCHEN DRAWERS, CABINETS NOT ON RIGHT, ROACH EGGS IN CABINETS.

Outstanding Inspections

Case Number: T04DV00922
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00922
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/27/2004 INSP - INITIAL CODE ENFORCMENT JHURD Approved 12/7/04, VISITED SITE, TOOK PICTURES, C-15 ASST. MET WITH RESIDENT ESTHER, STARTED AT ELECTRICAL SERVICE METERS, FOUND BOTH METER AND BREAKER PANEL LOOSE FROM WALL, HAS BEEN UPGRADED TO 100 AMP SERVICE, DEAD PLATE MISSING BLANK COVER PLATE, ALSO 516 MISSING BLANK COVERS, BOTH SERVICES ARE LACKING PROPER LABELING OR MARKING, 514, PATIO PORCH ROOF APPEARS TO HAVE BEEN REPLACED, LACKS PROTECTIVE COVERINGS ON PORCH EAVES, EAST SIDE ROOF SHOWS DETERIORATION AT PLYWOOD SHEETING, FRONT WINDOW SHOWS DETERIORATION, WOOD ROTTED AND MISSING IN AREAS, FRONT DOOR MISSING CENTER DOOR HINGE, FRONT DOOR LACKS PROPER WEATHER PROTECTION, LEFT SIDE, TOP, BOTTOM DOES NOT PROPERLY SEAL, CONVENIENCE OUTLET NOT INSTALLED PROPERLY SUNK INTO WALL, NOT FLUSH MOUNTED, WALL HEATER FOR LIVING ROOM AND BEDROOM DOES NOT OPERATE, T-STAT WIRES HANGING NO CONNECTION, NO PILOT, HEATER APPEARS TO HAVE BEEN REPLACED, DWELLING SHOWS EVIDENCE OF ROOF LEAK, TILES ON CEILING WET AND STAINED, BEDROOM LIGHT SWITCH MISSING COVER PLATE, HAS BROKEN OUTLET, KITCHEN CONVENIENCE OUTLET ABOVE SHOWS REVERSE POLARITY UNDER TEST, NOT GFCI PROTECTED, NO HOT WATER AT KITCHEN SINK, NO GAS AT COOK STOVE, IMPROPER WIRING AT RANGE HOOD USING EXTENSION CORD TO SUPPLY POWER IN LIEU OF HARD WIRING, ALSO DOES NOT OPERATE, WINDOW IN HALL WAY BY BATH BROKEN, REAR DOOR LACKS PROPER WEATHER PROTECTION, BATHROOM WINDOW DOES NOT OPERATE AS INTENDED, WILL NOT OPEN LACKS VENTILATION, BATH CONVENIENCE OUTLET NOT GFCI PROTECTED, HAS ADDED CONVENIENCE OUTLET, REAR DOOR JAMB LACKS PROTECTIVE COATING, RAW WOOD, WOOD FRAME WINDOW TO NORTH-EAST CORNER DETERIORATED, HOT WATER TANK EMERGENCY SHUT OFF WRONG EQUIPMENT, STUCCO DETERIORATING IN AREA, METAL WIRING SHOWING THROUGH, METAL CABINET TO HOT WATER TANK NOT PROPERLY INSTALLED, HOT WATER TANK DETERIORATING, RUSTED, COLD WATER HANDLE TO MAIN WATER SUPPLY MISSING SHUT OFF HANDLE, REAR PORCH MADE OF 2X4, OVER SPANED, USING 4X4 AS HEADER, 10' SPAN BETWEEN SUPPORT POST, 4X4 SUPPORT POST DETERIORATED AT BASE, SOME ARE SCABED TOGETHER AT TOP, USING CLEAN OUT AS PLUMBING SYSTEM, LACKS TRAPS ALLOWING SEWER GASES TO ESCAPE ON BACK PORCH, NOT PROPERLY SUPPORTED, VENT PIPE TO SHORT, CHECKED GAS METERS, THERE ARE 3 UNITS ON SITE, ALL 3 GAS METERS ARE RED TAGED, RESIDENT ESTHER STATED THAT THERE IS A LEAK IN SYSTEM THAT IS WHY THEY ARE OFF, I CALLED AND TALKED WITH SOUTH WEST GAS, NOTHING SHOWS THERE IS ANY THING WRONG AT THAT ADDRESS, RESIDENT HAS NOT APPLIED TO HAVE GAS RESTORED, APPEARS TO BE ONLY RESIDENT ISSUE, WILL TALK WITH RESIDENT ABOUT RESORING GAS.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00922
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
12/06/2004 CONTACTED BY PHONE
09/14/2005 NOTICE OF VIOLATION ISSUED
10/27/2006 VIOLATION CLOSED

Documents

File Name Document Type  
NOTES 05-26-06.PDF DOCUMENTS VIEW
NOTES 06-21-06.PDF DOCUMENTS VIEW
NOTES 10-04-06.PDF DOCUMENTS VIEW
NOV 09-13-05.PDF DOCUMENTS VIEW