Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T04DV00890
Case Details
Entered Date:
11/08/2004
Applicant:
STAGMO INVESTMENTS LLC
Description:
COMPLAINT RE:MIN HOUSING-T.D.P. CALL OUT. HAZARDOUS LIVING CONDITION: ELECTRICAL, STRUCTURAL, ROACH & SPIDER INFESTATION, JUNK & DEBRIS INTERIOR & EXTERIOR.
Completed Inspections
Case Status: COMPLIAN
Case Number: T04DV00890
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/05/2004 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE, MET W/ OFFICER M. LAPEDUS FROM T.P.D. ALSO MET W/ MAYRA NAVARRO FROM CHILD PROTECTIVE SERVICES, THERE ARE 4 CHILDREN @ SITE, ALL FEMALE AGES 4-11YRS, UPON ENTERING MOBILE HOME FOUND, MAJOR ROACH INFESTATION, SPIDER INFESTATION, DWELLING VERY DIRTY, KITCHEN: LITE SWITCH ENERGIZED HANDING OUT OF WALL, OUTLET HANGING OUT OF WALL, ROACH DROPPINGS, SPIDER WEBS ON WALLS, KITCHEN WINDOWS BROKEN OUT, KITCHEN OUTLET SOUTH WALL WIRES (BARE) HANGING OUT OF WALL, PROPANE CYLINDER IN PANTRY CLOSET, DWELLING HAS NO GAS, PROPANE USED FOR COOK STOVE, REFRIGERATOR BEING SUPPLYED POWER BY EXTENSION CORD, KITCHEN CABNET DOORS FALLING OFF, OIL BEING STORED UNDER SINK, KITCHEN CABNET UNDER SINK, DETERIORATED, ROTTED THROUGH, EXPOSED WIRING ABOVE KITCHEN SINK HANGING OUT OF BOX, KITCHEN FLOOR COVERING MISSING IN AREAS, WET, EXTENSION CORD FEEDING FRIG IS FROM L/R OUTLET, OUTLET WORN, EXTENSION CORD HAS BROKEN PLUG, OUTLET ON, LACKS COVER PLATE, L/R WEST WALL WIRES STICKING OUT OF WALL, HALLWAY DRYWALL DETERIORATED FROM LEAK, CEILING DETERIORATED FROM LEAK, HEATER T-STAT HANGING FROM WALL, HALLWAY ELECT BOX OPEN, WIRES HANGING AND CUT OFF, BEDROOM (1) HAS SQUIRREL CAGE & MOTOR TIED TO EXTENSION CORD FOR COOLING, CEILING LITE FIXTURE MISSING, WIRES HANGING, LITE SWITCH AND OUTLET MISSING COVER, OUTLET BURNT, CABNETRY MISSING ALL FRONT, HALLWAY OUTLET HANGING WIRES, BOX HANGING FROM WALL, HEATER DOES NOT OPERATE, VERY DIRTY, S.W. GAS HAS TAGED HEATER FOR NO USE DUE TO CRACK HEAT EXCHANGER (3-24-99). BATH: LITE FIXTURE MISSING, EXPOSED WIRING HANGING FROM CEILING, OUTLET BROKEN, COMPLETE SHOWER AREA DETERIORATED, EAST SHOWS EXPOSED INSULATION, SOUTH WALL IS EXPOSED DRYWALL, NORTH WALL MISSING, BOTTOM FLOORING MISSING FROM UNDER TUB, TOILET LEAKS WHEN FLUSHED, ALL CABNETRY DETERIORATED, ROTTED THROUGH, SEWER BACKING UP INTO STRUCTURE, BUCKET UNDER BATH SINK CATCHING WATER FROM LEAK. BEDROOM (2): LIGHT FIXTURE LAYING ON FLOOR PLUGED INTO POWER STRIP & EXTENSION CORD, WIRE SPLICED TOGETHER, INTERIOR SUB-PANEL HAS JUMPER WIRE TO SUPPLY POWER FROM ONE FUSE TO ANOTHER, NO EGRESS FROM B/R, EXTERIOR HAS TRASH & DEBRIS SCATTERED ABOUT SIDES & BACK, JMV, NOT CURRENTLY REGISTERED ON SITE, STORAGE SHED BUILT ON WESTSIDE AND ATTACHED TO STRUCTURE, ANOTHER SMALL STORAGE SHED ON WESTSIDE, FINISH EXTERIOR INSP. ON MONDAY 11/8/04. SHUT DOWN DWELLING FOR ALL HAZARDOUS ELECTRICAL ISSUES, DONE NOV POSTED ON DWELLING. |
12/29/2004 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | 12/29/04, REVISITED SITE, TOOK PICTURES, FOUND MOBILE HOME SECURED AT THIS TIME, STRUCTURE VAC. AND SECURED, 1 FOLLOW UP 30 DAYS |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00890
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
11/08/2004 | NOTICE OF VIOLATION ISSUED |
12/28/2004 | COURT ORDERED ABATEMENT |
01/31/2005 | VIOLATION CLOSED |