Case: T04DV00846
Case Details
Entered Date:
10/21/2004
Applicant:
LEWIS FERN
Description:
COMPLAINT:MIN HOUSING-NO HEATER. NO WEATHERSTRIPPING ON DOORS AND WINDOWS. LEAK FROM COOLER THROUGH WALL TO ELECTRICAL OUTLET.
Outstanding Inspections
Case Number: T04DV00846
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: VOID
Case Number: T04DV00846
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2004 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED STE, CALL OUT FROM INSP II RICK. ARRIVED ON SITE NO ONE HOME, CALLED CELL # RESIDENT WILL BE HERE IN ABOUT 15 MIN. WAITED ON SITE. FOUND ON EXTERIOR NEW WROUGHT IRON SECURITY BARS ON WINDOWS NOT BREAK AWAY, NO DOUBLE LUGGING IN METAL BOXES, HOT WATER TANK CAN NOT TURN COLD WATER SUPPLY VALVE OFF, 1/2" COPPER LINE FOR HOT WATER TANK, GOING INTO STRUCTURE, OLD GAL VALVE, NO PRV DRAIN LINE, FRONT DOOR WEATHER STRIP, OUTLET SHOWS OPEN GROUND UNDER TEST, HOLE IN L/R WALL (EAST) OUTLET EAST WALL SHOWS OPEN GROUND UNDER TEST, KITCHEN WIRED CORRECTLY, NOT GFCI PROTECTED, KITCHEN EXHAUST FAN DOES NOT OPERATE, COPPER LINES ADDED TO HOT WATER KITCHEN, STOVE CONNECTOR NOT SECURED TO WALL, L/R WALL WEST OUTLET GONE, OPEN HOLE, REAR DOOR LACKS WEATHER PROTECTION, L/R WINDOWS SEALED CLOSED, WROUGHT IRON, REAR DOOR FOR EGRESS, OUTLET WEST WALL BURNT, SHOWS OPEN GROUND, L/R CEILING SAGS ON NORTHSIDE, ROOM TO WEST B/R WINDOWS TO SMALL FOR EGRESS, OUTLET SOUTH WALL REVERSED POLARITY, OUTLET WEST WALL OPEN GROUND, BATH ROOM DOOR 6', OUTLET OPEN GROUND, NOT GFCI PROTECTED, CAN NOT USE SINK VANITY TO CLOSE TO TOILET, SMELLED GAS @ WATER HEATER, RESIDENT CALLED S.W. GAS TO CHECK FOR LEAK, FLUE PIPE TO SHORT, S.W. GAS TECH. DID SHOW ON PROPERTY, FOUND 2 LEAKS ON SITE, 1 LEAK AT HOT WATER TANK SUPPLY TUBE, LEAK 2 WAS FOUND UNDER GROUND AT FOUNDATION WHERE GAS SUPPLY LINE GOES INTO UNIT, S.W. GAS SHUT DOWN ALL GAS SUPPLY AT METER, THIS ONLY EFFECTS THE HOT WATER TANK, NO GAS APPLIANCES IN DWELLING, DWELLING LACKS ANY SOURCE OF HEATING, COOK STOVE ELECT, MET W/ OWNER JOHN KAUFMAN ON SITE, S.W. GAS WENT OVER NATURAL GAS SUPPLY ISSUES, I WENT OVER MOST ALL OTHER ISSUES, EXPLAINED TO JOHN OPTIONS ON GAS SUPPLY, METER FOR 35 W. IS IN YARD OF 37 W. RILLITO APPROX. 100 TO 150 FEET AWAY, OPTION (1) RUN NEW LINE FROM THIS POINT, OPTION (2) CALL S.W. GAS AND ASK FOR RELOCATION, MOVING METER TO YARD OF 35 W. WHERE IT BELONGS, OPTION (3) CHANGE HOT WATER TANK TO ELECT. UNIT HAS NEWER ELECT UP GRADE TO 125 AMP, BREAKER TYPE, ALSO WENT OVER, ISSUE OF NO HEAT IN DWELLING, NEEDS TO INSTALL HEAT IN ALL HABITAL ROOMS, TALKED ABOUT ELECT BASE BOARD HEAT, AS TALKING W/ OWNER WENT OVER SOME OTHER ISSUES FOUND, I STATED TO OWNER I THINK THIS STRUCTURE USE TO BE A SHED, HE INTURNED STATED USE TO BE RAIL ROAD CAR, B/R CEILING UNDER 7', GAS LINE INTO STRUCTURE IS ONLY APPROX. 3-4", BELOW GRADE SHOULD BE 12", BELOW GRADE BATHROOM SHOWS EVIDENCE OF BEING INSTALLED W/O PERMITS. F/U RESEARCH @ D.S.D. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00846
Case Status: VOID
Total Completed Case Activity Conditions: 3
| Date | Name |
| 11/03/2004 | CONTACTED BY PHONE |
| 12/20/2004 | COURT ORDERED ABATEMENT |
| 12/20/2004 | NOTE: |