Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

10/07/2004

Applicant:

UMBAUGH ELIZABETH

Description:

COMPLAINT:MIN HOUSING: TPD CALL OUT

Outstanding Inspections

Case Number: T04DV00822
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
10/07/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Correction Required VISITED SITE ON TPD CALL OUT, TPD CONCERNED ABOUT LIVING CONDITION, WALKED INTERIOR AND EXTERIOR OF STRUCTURE TO ACCESS HEALTH AND SAFETY ISSUES. WALK THROUGH DID FIND SAFETY ISSUES AND ARE AS FOLLOWS: 1. WEATHER PROOFING - STRUCTURE WAS RAIDED BY TPD SEVERAL WINDOWS AND SLIDING GLASS DOORS WERE BROKEN AND SHARP PIECES ARE EXPOSED AND READILY ACCESSIBLE . 1. ELECTRICAL - INTERIOR SUB-PANEL MISSING COVER AND HAS EXPOSED ELECTRICAL CONDUCTORS ACCESSIBLE. 2. SEVERAL SWITCH PLATES AND RECEPTACLE COVERS WERE FOUND MISSING THROUGHOUT STRUCTURE. 3. BATHROOM LIGHT FIXTURE NOT SECURED PROPERLY TO WALL AND CONTROL KNOB MISSING FROM POSSSIBLE DIMMER SWITCH. 4. 2 BEDROOM WALLS HAVE DRYWALL DAMAGE AND HAVE EXPOSED ELECTRICAL CONDUCTORS. PLUMBING 1. HOT WATER B-VENT SYSTEM HAS BEEN DISMANTLED. 2. TPR VALVE DRAIN PIPE DOES NOT MEET CODE REQUIREMENTS, NO DRAIN PIPE HAS BEEN INSTALLED. 3. FLAMMABLE ITEMS WERE FOUND STORED IN TANK AREA. INTERIOR FEATURES 1. DRYWALL DAMAGE THROUGH OUT INTERIOR OF STRUCTURES, BEDROOMS, HALLWAY. 2. INTERIOR FULL OF CLUTTER IN LIVING ROOM/FAMILY ROOM. FAMILY ROOM USED AS BEDROOM. EXTERIOR FEATURES 1. LARGE AMOUNTS OF TRASH AND DEBRIS THROUGOUT BACK YARD SUCH AS SOFAS AND SEVERAL LARGE ITEMS, COMBUSTABLE WASTE. WILL ISSUE NOV WITH DESIGNATED TIME FRAME FOR CLEARING OF CLUTTER FOR SAFE EGRESS, MECHANICAL CONTRACTOR TO REPAIR B-VENT AND PLUMBER TO INSTALL TPR DRAIN, SECURE BATHROOM LIGHT FIXTURE. INSTALL RECEPTACLE COVER PLATES. PICTURES WERE TAKEN AND NOV WAS HAND DELIVERED. ELECTRICAL AND PLUMBING INTERIOR SUB-PANEL WAS REINSTALLED BY DNR INSPECTOR H. LOPEZ AS WELL AS FLUE VENT ASSEMBLY. FIRE SAFETY SMOKE DETECTOR WAS IN WORKING CONDITION.
12/16/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Correction Required VISITED SITE, MET WITH OWNER, WENT OVER UNABATED ITEM SLIDING GLASS DOOR HAS BEEN BOARDED UP, 2 SET OF WINDOWS IN FRONT HAVE NOT BEEN REPLACED, TRP DRAIN FROM HOT WATER HEATER NOT COMPLETED. MIDDLE BEDROOM FLOORING AND DOORWAY HAS NOT BEEN COMPLETED AND HEATING SYSTEM LACKING T-STAT FOR OPERATION. 80% OF TRASH AND DEBRIS HAS BEEN REMOVED FROM EXTERIOR OF YARD. OWNER LIZ STATED DREW HAS NOT BEEN ABLE TO COMPLETE REPAIRS DUE TO FINANCES, PROBLEMS WITH HIS DOG. LIZ STATED DREW IS AWARE WHAT NEEDS TO BE COMPLETED AND INSPECTOR SHOULD TALK TO HIM. DREW IS DAUGHTER'S BOYFRIEND. BASICALLY NO PROGRESS HAS BEEN MADE. OWNER IS ON ADMINISTRATIVE LEAVE FROM WORK AND STATED SHE ONLY RECEIVES 1/2 HER PAY CHECK. AND IS UNABLE TO AFFORD REMAINING REPAIRS AT THIS TIME. INFORMED HER INSPECTOR WILL DISCUSS CASE WITH INSPECTOR II, RICK SALDATE BEFORE MOVING FORWARD WITH CASE. EXTENTION WILL DEPEND ON CONSULTATION WITH INSPECTOR II. INFORMED OWNER CITATION MAYBE ISSUED AND DNR WILL CONTACT HER IF CITATION WILL BE SUBMITTED TO PROSECUTOR. ALSO INFORMED HER CPS IS REQUESTING STATUS OF CASE. PICTURES TAKEN.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00822
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
10/11/2004 CONTACTED BY PHONE
03/10/2005 CONTACTED IN PERSON
10/12/2004 NOTICE OF VIOLATION ISSUED
02/15/2005 LONG FORM CITATION
10/11/2004 COURT ORDERED ABATEMENT
03/11/2005 VIOLATION CLOSED