Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING

Entered Date:

05/17/2004

Applicant:

RANDALL LAURA A

Description:

COMPLAINT:MIN HOUSING-HOLE IN KITCHEN FLOOR, UNCAPPED WIRES STICKING OUT OF ROOF. NO WINDOW OR EXHAUST FAN IN BATHROOM. NO SMOKE DETECTORS. LIVINGROOM OUTLET HAS NO COVER.

Outstanding Inspections

Case Number: T04DV00413
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
05/18/2004 INSP - INITIAL CODE ENFORCMENT RHENDRIC Correction Required INSPECTION. NO GAS SHUT OFF VALVE AT GAS STOVE, NO SMOKE ALARMS, RECEPTACLES HANGING OUT OF WALLS, HOLE IN KITCHEN FLOOR, THRESHOLD LOOSE AT FRONT DOOR, NEED BLANKS INSTALLED AT BREAKER BOX, DOOR HANDLE MISSING AT BATHROOM, PANELING FALLING OFF IN KITCHEN UNDER COUNTER, EXTENSION CORD RUNNING TO ROOF, LIVING ROOM WINDOW OUT OF PLUMB LEAVING A ONE INCH GAP TO THE EXTERIOR, HOLE IN LIVING ROOM CEILING. POSSIBLE WORK WITHOUT PERMITS, DOING RESEARCH OF NEW ELECTRIC SERVICE AND A 16X24 WORKSHOP WITH ELECTRIC, ONE FOOT FROM PROPERTY LINE. WWOP WILL BE REFERRED TO DSD FOR COMPLIANCE. NOV TO GO OUT. PICTURES IN FILE.

Completed Inspections

Case Status: VOID
Case Number: T04DV00413
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/20/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE MADE CONTACT WITH TENANT QUENTIN, TENANT STATED THEY WERE NOT EXPECTING INSP. ARRANGEMENT WAS FOR INSP. TO CALL & SCHEDULE APPOINTMENT. INFORMED TENANT INFORMATION FROM OFFICE WAS TENANTS WERE EXPECTING D.N.R. INSP. ON 10/20/04. ASKED TENANT ABOUT VIOLATIONS, TENANT STATED SEVERAL VIOLATIONS HAD NOT BEEN TAKEN CARE OF ON INTERIOR OF STRUCTURE, BUT WOULD NOT ALLOW INSP. TO ENTER DUE TO WIFE BEING UNDER MEDICATION. TENANT STATED EXTERIOR VIOLATIONS CONCERNING ELECTRICAL RECEPTACLE AT REAR OF STRUCTURE HAD NOT BEEN ABATED. ELECTRICAL (1) J-BOX NOT WEATHER PROOF, 6 GANG RECEPTACLES HAS BEEN INSTALLED & COVER PLATE HAS BEEN REMOVED & OR LACKING. (2) TENANT STATED T.E.P. DENIED INSTALLATION OF OVERHEAD POWER SUPPLY DUE TO LARGE TREE HAS NOT BEEN TRIMED TO ALLOW PROPER CLEARANCE. INFORMED TENANT D.N.R. INSPECTOR COULD NOT DO PROPER INSPECTION DUE TO NOT BEING ALLOWED ENTRY INTO UNIT. D.N.R. INFORMED TENANT QWENTIN TO MAKE ARRANGEMENTS FOR TUESDAY, 10/26/04 FOR PROPER INSPECTION OF INTERIOR VIOLATION. TENANT STATED WASP PROBLEM HAS BEEN TAKEN CARE OF & D.S.D. IS DEALING WITH W/O/P ISSUES. APPEARS 2 SERVICES MAY BE SCHEDULED FOR STRUCTURE. TENANT STATED ELECTRICAL MAY BE IN THE WORK FOR STRUCTURE IN BACK. FW/UP 10/26/04.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00413
Case Status: VOID
Total Completed Case Activity Conditions: 5
Date Name
12/06/2004 CONTACTED BY MAILING
05/27/2004 NOTICE OF VIOLATION ISSUED
05/27/2004 COURT ORDERED ABATEMENT
12/29/2004 VIOLATION CLOSED
10/27/2004 CONTACTED BY PHONE