Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

INVALID

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

03/10/2004

Applicant:

OLSON SCOTT W

Description:

COMPLAINT:MIN HOUSING-WATER HEATER VENT FLUE IS NOT TO CODE. WHEN TENANT PUTS ON COOLER, FLUE GAS COMES BACK INTO HOUSE. INSPECTION ON 5/12/04 BY DNR INSPECTOR FOUND EVIDENCE OF WORK WITH OUT PROPER PERMITS & INSPECTION. ADDTION OF LAUNDRY ROOM WITH ELECTRICAL & PLUMBING. STRUCTURAL ALTERATION TO CARPORT. FLUE VENT THOUGH ROOF IN NOT REQUIRED B-VENT SYSTEM. CARPORT IN VOILATION OF ZONING SET-BACK ORDENANCE

Outstanding Inspections

Case Number: T04DV00210
Case Status: INVALID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: INVALID
Case Number: T04DV00210
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/12/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VACANT & SECURED. VISITED SITE STRUCTURE IS VACANT & SECURED AT THIS TIME. STRUCTURE UNDER RENOVATION, ALTERATIONS ARE BEING DONE TO CARPORT AREA, EVIDENCED BY NEW 2" X 6" BEAMS SCABED TOGETHER & SPANING APPROX. 10 FEET. BEAMS HAVE BEEN INSERTED INTO NORTH BLOCK WALL. CARPORT IN VIOLATION OF ZONING SET BACK REQUIREMENTS. POSSABLE ADDITION OF LAUNDRY ROOM WITH ELECTRICAL & PLUNBING. WORK WITH OUT PERMITS & INSPECTIONS ARE EVIDENCED BY ADDTION OF 220 CIRCUIT & ELECTRICAL CONDUCTORS NOT IN CONDUIT. WATER LINES HAVE NOT BEEN PROPERTY SECURED TO WALL. COMPLAINT MADE BY TENANT STATED FLUE VENT WAS TO CLOSE TO COOLER. ON INSPECTION INSP. NOTICED NEW FLUE VENT APPROX. 6 INCH ROUND HAS BVEEN INSTALLED & IS NOT REQUIRED B-VENT SYSTEM. INTERIOR IS BEING REMOLDED. STAIRS TO WHAT APPEARS TO BE A LOFT HAVE BEEN REMOVED STRUCTURE HAS HAD ELECTRICAL UP-GRADE. NO PERMITS ARE ON FILE FOR UP-GRADE. CITY OF TUCSON HAS NO JURIDICTION ON VACANT & SECURED STRUCTURE. COMPLAINT IS INVALID CLOSE CASE. PICTURES WERE TAKEN. REFERRAL WILL BE MADE TO ZONING & DSD FOR WORK WITH OUT PROPER PERMITS & INSPECTIONS. INFORMATION WILL BE FORWARDED ALSO.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00210
Case Status: INVALID
Total Completed Case Activity Conditions: 1
Date Name
03/16/2004 CONTACTED BY PHONE

Documents

File Name Document Type  
None DOCUMENTS VIEW